0
RESEARCH PAPERS

Air Release During Column Separation

[+] Author and Article Information
Muin Baasiri

The American University of Beirut, Beirut, Lebanon

J. Paul Tullis

Utah State University, Logan, Utah

J. Fluids Eng 105(1), 113-118 (Mar 01, 1983) (6 pages) doi:10.1115/1.3240926 History: Received March 20, 1981; Online October 26, 2009

Abstract

Air release caused by column separation in a pipeline was investigated in a test facility where column separation could be generated for any desired length of time. The temperature, pressure, amount of dissolved air, and the other variables affecting the process were carefully controlled. Tests were made for cases where there was no initial free air in the system and for cases where there was some initial free air. The parameters influencing air release were identified and empirical equations developed for predicting the amount of air released during each cycle of column separation.