0
RESEARCH PAPERS

Hydromagnetic Stability of Current-Induced Flow in a Small Gap Between Concentric Cylinders

[+] Author and Article Information
Min-Hsing Chang

Department of Mechanical Engineering, Yung-Ta College of Technology, Pingtung, Taiwan 909, ROC

Cha’o-Kuang Chen

Department of Mechanical Engineering, National Cheng Kung University, Tainan, Taiwan 701, ROC

J. Fluids Eng 121(3), 548-554 (Sep 01, 1999) (7 pages) doi:10.1115/1.2823503 History: Received January 07, 1998; Revised May 17, 1999; Online December 04, 2007

Abstract

A linear stability analysis has been carried out for hydromagnetic current-induced flow. A viscous electrically conducting fluid between concentric cylinders is driven electromagnetically by the interaction of a superimposed radial current and a uniform axial magnetic field. The assumption of small-gap approximation is made and the governing equations with respect to nonaxisymmetric disturbances are derived and solved by a direct numerical procedure. Both of the two different types of boundary conditions, namely ideally conducting and weakly conducting walls, are considered. For 0 ≤ Q ≤ 5000, where Q is the Hartmann number, which represents the strength of magnetic field in the axial direction, it is found that the instability sets in as a steady secondary flow for the case of weakly conducting walls but not for ideally conducting walls. For ideally conducting walls, it is demonstrated that the onset mode is due to nonaxisymmetric rather than axisymmetric disturbances as Q exceeds a certain critical value. The transition of the onset of instability from axisymmetric modes to nonaxisymmetric modes is discussed in detail and the possibility of axisymmetric oscillatory modes is examined. The values of the radial current density required for the appearance of secondary flow are also determined. Furthermore, the predictions of present numerical results are found to be in agreement with previous experimental studies.

Copyright © 1999 by The American Society of Mechanical Engineers
Your Session has timed out. Please sign back in to continue.

References

Figures

Tables

Errata

Discussions

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related Journal Articles
Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In