0
TECHNICAL BRIEFS

A Linear Stability Analysis for an Improved One-Dimensional Two-Fluid Model

[+] Author and Article Information
Jin Ho Song

Korea Atomic Energy Research Institute, P.O. Box 105, Taejon 305-600, Korea. e-mail: dosa@kaeri.re.kr

J. Fluids Eng 125(2), 387-389 (Mar 27, 2003) (3 pages) doi:10.1115/1.1537256 History: Received April 25, 2001; Revised September 25, 2002; Online March 27, 2003
Copyright © 2003 by ASME
Your Session has timed out. Please sign back in to continue.

References

Ramshaw,  J. D., and Trapp,  J. D., 1978, “Characteristics, Stability, and Short-Wavelength Phenomena in Two-Phase Flow Equation Systems,” Nucl. Sci. Eng., 66, pp. 93–102.
Stuhmiller,  J. H., 1977, “The Influence of Interfacial Pressure Forces on the Character of Two-Phase Flow Model Equations,” Int. J. Multiphase Flow, 3, pp. 551–560.
Lahey,  R. T., Cheng,  L. Y., Drew,  D. A., and Flaherty,  J. E., 1980, “The Effect of Virtual Mass on the Numerical Stability of Accelerating Two-Phase Flow,” Int. J. Multiphase Flow, 6, pp. 281–294.
Song,  J. H., and Ishii,  M., 2001, “On the Stability of a One-Dimensional Two-Fluid Model,” Nucl. Eng. Des., 204, pp. 101–115.
Ishii,  M., and Mishima,  K., 1984, “Two-Fluid Model and Hydrodynamic Constitutive Relations,” Nucl. Eng. Des., pp. 107–126.
Pokharna,  H., Mori,  M., and Ransom,  V. H., 1997, “Regularization of Two-Phase Flow Models: A Comparison of Numerical and Differential Approaches,” J. Comput. Phys., 134, pp. 282–295.
Ishii,  M., and Zuber,  N., 1979, “Drag Coefficient and Relative Velocity in Bubbly, Droplet or Particulate Flows,” AIChE J., 25(5), pp. 843–855.
Ishii, M., 1977, “One Dimensional Drift-Flux Model and Constitutive Equations for Relative Motion between Phases in Various Two-Phase Flow Regimes,” Paper No. ANL-77-47.
Van der Welle,  R., 1985, “Void Fraction, Bubble Velocity, and Bubble Size in Two-Phase Flow,” Int. J. Multiphase Flow, 11(3), pp. 17–34.

Figures

Grahic Jump Location
Plots of Q for bubbly and slug flow at density ratio of 0.1 and 0.001
Grahic Jump Location
Plots of P for bubbly and slug flow at density ratio of 0.1 and 0.001

Tables

Errata

Discussions

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related Journal Articles
Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In