CFD analysis has been conducted to obtain information on heat losses, velocity and temperature distribution of large molten salt Thermal Energy Storage (TES) systems. A two-tank 880 MWh storage system was modeled according to the molten salt TES containment design proposed for the 50 MWel commercial parabolic trough solar thermal power plants in Spain. Heat losses were established using the Finite Element Method (FEM), and used to determine the boundary conditions for the subsequent two- and three-dimensional Computational Fluid Mechanics (CFD) calculations. The investigations reveal that a high heat loss flux occurs at the lower edges of the salt storage tanks (between side wall and bottom plate). Thus the maximum temperature difference can be found at this location, resulting in the onset of local solidification within 3.25 days in the case of the empty cool tank. As a consequence, the detailed design of the lower edge has a large impact on both the overall heat losses and the period until the onset of local solidification.
Skip Nav Destination
ASME 2008 2nd International Conference on Energy Sustainability collocated with the Heat Transfer, Fluids Engineering, and 3rd Energy Nanotechnology Conferences
August 10–14, 2008
Jacksonville, Florida, USA
Conference Sponsors:
- Advanced Energy Systems Division and Solar Energy Division
ISBN:
978-0-7918-4320-8
PROCEEDINGS PAPER
CFD Analysis of the Cool Down Behaviour of Molten Salt Thermal Storage Systems
Jan Schulte-Fischedick,
Jan Schulte-Fischedick
German Aerospace Center, Stuttgart, Germany
Search for other works by this author on:
Rainer Tamme,
Rainer Tamme
German Aerospace Center, Stuttgart, Germany
Search for other works by this author on:
Ulf Herrmann
Ulf Herrmann
Flagsol GmbH, Koeln, Germany
Search for other works by this author on:
Jan Schulte-Fischedick
German Aerospace Center, Stuttgart, Germany
Rainer Tamme
German Aerospace Center, Stuttgart, Germany
Ulf Herrmann
Flagsol GmbH, Koeln, Germany
Paper No:
ES2008-54101, pp. 515-524; 10 pages
Published Online:
June 22, 2009
Citation
Schulte-Fischedick, J, Tamme, R, & Herrmann, U. "CFD Analysis of the Cool Down Behaviour of Molten Salt Thermal Storage Systems." Proceedings of the ASME 2008 2nd International Conference on Energy Sustainability collocated with the Heat Transfer, Fluids Engineering, and 3rd Energy Nanotechnology Conferences. ASME 2008 2nd International Conference on Energy Sustainability, Volume 2. Jacksonville, Florida, USA. August 10–14, 2008. pp. 515-524. ASME. https://doi.org/10.1115/ES2008-54101
Download citation file:
56
Views
Related Proceedings Papers
Related Articles
Optimal Design of a Molten Salt Thermal Storage Tank for Parabolic Trough Solar Power Plants
J. Sol. Energy Eng (November,2009)
Comparative Analysis of Single- and Dual-Media Thermocline Tanks for Thermal Energy Storage in Concentrating Solar Power Plants
J. Sol. Energy Eng (June,2015)
Test Results of Concrete Thermal Energy Storage for Parabolic Trough Power Plants
J. Sol. Energy Eng (November,2009)
Related Chapters
Subsection NCA—General Requirements for Division 1 and Division 2
Companion Guide to the ASME Boiler and Pressure Vessel Code, Volume 1, Third Edition
Subsection NCA—General Requirements for Division 1 and Division 2
Companion Guide to the ASME Boiler & Pressure Vessel Code, Volume 1, Second Edition
Numerical Study on Dynamic Charging Performance of Packed Bed Using Spherical Capsules Containing N-Tetradecane
Inaugural US-EU-China Thermophysics Conference-Renewable Energy 2009 (UECTC 2009 Proceedings)