The main reason for the revision of total hip replacements is aseptic loosening, caused by stress shielding and wear particle induced osteolysis. In order to detect an implant loosening early, the osseointegration of endoprosthetic implants must be measured exactly. Currently applied diagnostic methods, such as standard radiographs and clinical symptomatology, often result in an imprecise diagnosis. A novel radiation-free method to improve the diagnostic investigation of implant loosening is presented. The osseointegration of an implant can be identified using mechanical magnetic sensors (oscillators), which impinge on small membranes inside an implant component, e.g., the femoral hip stem. The maximum velocity after impingement of the oscillator depends on the osseointegration of the implant. Excitation of the oscillator is realized by a coil outside the human body. Another external coil is used to detect the velocity of the oscillator. To demonstrate the principle of the novel loosening sensor, an overdimensioned test device was designed to measure simulated loosening phases in the first experimental tests with different material layers. The overdimensioned test device of the loosening sensor showed significant differences in the various phases of fixation. Analysis of the membrane without any material layer in the case of advanced loosening resulted in a 23% higher maximum velocity compared to an attached artificial bone layer. Based on these preliminary results, the sensor system shows potential for the detection of implant loosening. Moreover, the proposed system could be used in experimental applications to determine the quality of bioactive coatings and new implant materials.

References

1.
Malchau
,
H.
,
Herberts
,
P.
,
Eisler
,
T.
,
Garellick
,
G.
, and
Soderman
,
P.
, 2002, “
The Swedish Total Hip Replacement Register
,”
J. Bone Joint Surg. Am.
,
84-A
(
2
), pp.
2
20
.
2.
Temmermann
,
O. P.
,
Raijmakers
,
P. G.
,
Berkhof
,
J.
,
David
,
E. F.
,
Pijpers
,
R.
,
Molenaar
,
M. A.
,
Hoekstra
,
O. S.
,
Teule
,
G. J.
, and
Heyligers
,
I. C.
, 2006, “
Diagnostic Accuracy and Interobserver Variability of Plain Radiography, Subtraction Arthrography, Nuclear Arthrography, and Bone Scintigraphy in the Assessment of Aseptic Femoral Component Loosening
,”
Arch. Orthop. Trauma Surg.
,
126
, pp.
316
323
.
3.
Zhang
,
Y.
,
Putnam
,
A. W.
,
Heiner
,
A. D.
,
Callaghan
,
J. J.
, and
Brown
,
T.
, 2002, “
Reliability of Detecting Prosthesis/Cement Interface Radiolucencies in Total Hip Arthroplasty
,”
J. Orthop. Res.
,
20
, pp.
683
687
.
4.
Zilkens
,
K. W.
,
Wicke
,
A.
,
Zilkens
,
J.
, and
Büll
,
U.
, 1988, “
Nuclear Imaging in Loosening of Hip-Joint Endoprosthesis
,”
Arch. Orthop. Trauma Surg.
,
107
, pp.
288
292
.
5.
Lieberman
,
J. R.
,
Huo
,
M.
,
Schneider
,
R.
, and
Salvati
,
E.A.
, 1993,
“Evaluation of Painful Hip Arthroplasties – Are Technetium Bone Scans Necessary?”
J. Bone Joint Surg.
,
75
-B, pp.
475
478
.
6.
Huang
,
H. M.
,
Chiu
,
C. L.
,
Yeh
,
C. Y.
,
Lin
,
C. T.
,
Lin
,
L. H.
, and
Lee
,
S.Y.
, 2003, “
Early Detection of Implant Healing Process using Resonance Frequency Analysis
,”
Clin. Oral Impl. Res.
,
14
, pp.
437
443
.
7.
Glauser
,
R.
,
Sennerby
,
L.
,
Meredith
,
N.
,
Rée
,
A.
,
Lundgren
,
A. K.
,
Gottlow
,
J.
, and
Hämmerle
,
C.H.F.
, 2003, “
Resonance Frequency Analysis of Implants Subjected to Immediate or Early Functional Occlusal Loading – Successful Vs. Failing Implants
,”
Clin. Oral Impl. Res.
,
15
, pp.
428
434
.
8.
Lannocca
,
M.
,
Varini
,
E.
,
Cappello
,
A.
,
Cristofolini
,
L.
, and
Bialoblocka
,
E.
, 2007, “
Intra-Operative Evaluation of Cementless Hip Implant Stability: A Prototype Device based on Vibration Analysis
,”
Med. Eng. Phys.
,
29
, pp.
886
894
.
9.
Cristofolini
,
L.
,
Varini
,
E.
,
Pelgreffi
,
I.
,
Cappello
,
A.
, and
Toni
,
A.
, 2006, “
Device to Measure Intra-Operatively the Primary Stability of Cementless Hip Stems
,”
Med. Eng. Phys.
,
28
, pp.
475
482
.
10.
Pastrav
,
L. C.
,
Jaecques
,
S. V. N.
,
Jonkers
,
I.
,
van der Perre
,
G.
, and
Mulier
,
M.
, 2009, “
in vivo Evaluation of a Vibration Analysis Technique for the Peri-Operative Monitoring of the Fixation of Hip Prostheses
,”
J. Orthop. Surg. Res.
,
4
, pp.
1
10
.
11.
d’Hoedt
,
B.
,
Lukas
,
D.
,
Muhlbradt
,
L.
,
Scholz
,
F.
,
Schulte
,
W.
,
Quante
,
F.
, and
Topkaya
,
A.
, 1985, “
Das Periotestverfahren – Entwicklung und klinische Prüfung
,”
Deutsche Zahnaertzliche Zeitung
,
40
, pp.
113
125
.
12.
Rosenstein
,
A. D.
,
McCoy
,
G. F.
,
Bulstrode
,
C. J.
,
McLardy-Smith
,
P. D.
,
Cunningham
,
J. L.
, and
Turner-Smith
,
A. R.
, 1989, “
The Differentiation of Loose and Secure Femoral Implants in Total Hip Replacement using Vibrational Technique – An Anatomical and Pilot Clinical Study
,”
Proc. Inst. Mech. Eng.
,
203
, pp.
77
81
.
13.
Li
,
P. L. S.
,
Jones
,
N. B.
, and
Gregg
,
P. J.
, 1996, “
Vibration Analysis in the Detection of Total Hip Prosthetic Loosening
,”
Med. Eng. Phys.
,
18
, pp.
556
600
.
14.
Georgiou
,
A. P.
, and
Cunningham
,
J. L.
, 2001, “
Accurate Diagnosis of Hip Prosthesis Loosening using a Vibrational Technique
,”
Clin. Biomech.
,
16
, pp.
315
323
.
15.
Rowlands
,
A.
,
Duck
,
F. A.
, and
Cunningham
,
J. L.
, 2008, “
Bone Vibration Measurement using Ultrasound: Application to Detection of Hip Prosthesis Loosening
,”
Med. Eng. Phys.
,
30
, pp.
278
284
.
16.
Qi
,
G.
,
Mouchon
,
W. P.
, and
Tan
,
T. E.
, 2003, “
How Much can a Vibrational Diagnostic Tool Reveal in Total Hip Arthroplasty Loosening
,”
Clin. Biomech.
,
18
, pp.
444
458
.
17.
Paech
,
A.
,
Schulz
,
A. P.
,
Nassutt
,
R.
,
Keine
,
J.
,
Wenzl
,
M. E.
, and
Jurgens
,
C. H.
, 2007, “
Acoustic Properties of Femoral Components of Hip Endoprostheses Analysis using Frequency-Resonance Measurement in a Soft Tissue Simulation Model
,”
Res. J. Med. Sci.
,
1
(
2
), pp.
118
123
.
18.
Puers
,
R.
,
Catrysse
,
M.
,
Vandevoorde
,
G.
,
Collier
,
R. J.
,
Louridas
,
E.
,
Burny
,
F.
,
Donkerwolcke
,
M.
, and
Moulart
,
F.
, 2000, “
A Telemetry System for the Detection of Hip Prosthesis Loosening by Vibration Analysis
,”
Sens. Actuators
, A,
85
, pp.
42
47
.
19.
Marschner
,
U.
,
Grätz
,
H.
,
Jettkant
,
B.
,
Ruwisch
,
D.
,
Woldt
,
G.
,
Fischer
,
W. J.
, and
Clasbrummel
,
B.
, 2009, “
Integration of a Wireless Lock-In Measurement of Hip Prosthesis Vibrations for Loosening Detection
,”
Sens. Actuators
, A,
156
, pp.
145
154
.
20.
Verdonshot
,
N.
,
Dalstra
,
M.
, and
Huiskes
,
R.
, 1990, “
The Relevance of Implant Telemetry for Mechanical Analyses of Total Hip Arthroplasties
,”
Imp. Tele. Orthop.
, pp.
249
-
257
.
21.
Ruther
,
C.
,
Biemann
,
A.
,
Nierath
,
H.
,
Ewald
,
H.
,
Mittelmeier
,
W.
,
Bader
,
R.
, and
Kluess
,
D.
, 2010, “
A New Concept for Non-Invasive Radiation-Free Detection of Implant Loosening
,”
56th Annual Meeting of the Orthopaedic Research Society
,
New Orleans, Louisiana
,
USA
, March 6-9, 2010, pp.
2413
.
22.
Flansburg
,
L.
, and
Hudnut
,
K.
, 1979, “
Dynamic Solutions for Linear Elastic Collisions
,”
Am. J. Phys.
,
47
, pp.
911
914
.
23.
Nagurka
,
M.
, and
Huang
,
S.
, 2006, “
A Mass-Spring-Damper Model of a Bouncing Ball
,”
Int. J. Eng. Educ.
,
22
(
2
), pp.
393
401
.
24.
Meredith
,
N.
,
Alleyne
,
D.
, and
Cawley
,
P.
, 1996, “
Quantitative Determination of the Stability of the Implant-Tissue Interface using Resonance Frequency Analysis
,”
Clin. Oral. Impl. Res.
,
7
, pp.
261
267
.
You do not currently have access to this content.