Skip Nav Destination
Issues
June 2007
ISSN 0148-0731
EISSN 1528-8951
Technical Papers
Bone/Orthopedic
A CT-Based High-Order Finite Element Analysis of the Human Proximal Femur Compared to In-vitro Experiments
J Biomech Eng. June 2007, 129(3): 297–309.
doi: https://doi.org/10.1115/1.2720906
Topics:
Bone
,
Finite element analysis
,
Finite element model
,
Stress
,
Displacement
,
Young's modulus
,
Computerized tomography
,
Errors
The Effect of Cross-Sectional Stem Shape on the Torsional Stability of Cemented Implant Components
J Biomech Eng. June 2007, 129(3): 310–314.
doi: https://doi.org/10.1115/1.2720907
Cell
Constitutive Material Modeling of Cell: A Micromechanics Approach
J Biomech Eng. June 2007, 129(3): 315–323.
doi: https://doi.org/10.1115/1.2720908
Change in Properties of the Glycocalyx Affects the Shear Rate and Stress Distribution on Endothelial Cells
J Biomech Eng. June 2007, 129(3): 324–329.
doi: https://doi.org/10.1115/1.2720909
Topics:
Drag (Fluid dynamics)
,
Endothelial cells
,
Fluids
,
Porosity
,
Shear rate
,
Stress
,
Stress concentration
,
Fibers
,
Shear flow
Fluids/Heat/Transport
Numerical Assessment of Thermal Response Associated With In Vivo Skin Electroporation: The Importance of the Composite Skin model
J Biomech Eng. June 2007, 129(3): 330–340.
doi: https://doi.org/10.1115/1.2720910
Topics:
Biological tissues
,
Composite materials
,
Damage
,
Electroporation
,
Skin
,
Temperature
,
Joules
,
Electric fields
,
Electrical conductivity
,
Heating
Transport Characteristics of Expiratory Droplets and Droplet Nuclei in Indoor Environments With Different Ventilation Airflow Patterns
J Biomech Eng. June 2007, 129(3): 341–353.
doi: https://doi.org/10.1115/1.2720911
Topics:
Drops
,
Ventilation
,
Air flow
,
Ventilation equipment
,
Ceilings
,
Computer simulation
Radio-Frequency Ablation in a Realistic Reconstructed Hepatic Tissue
J Biomech Eng. June 2007, 129(3): 354–364.
doi: https://doi.org/10.1115/1.2720912
Topics:
Biological tissues
,
Flow (Dynamics)
,
Heat
,
Liver
,
Temperature
,
Tumors
,
Vessels
,
Blood flow
,
Blood
,
Ablation (Vaporization technology)
Numerical Simulation on Mass Transport in a Microchannel Bioreactor for Co-culture Applications
J Biomech Eng. June 2007, 129(3): 365–373.
doi: https://doi.org/10.1115/1.2720913
Topics:
Absorption
,
Bioreactors
,
Microchannels
,
Flow (Dynamics)
,
Boundary-value problems
,
Computer simulation
Multiphysics Simulation of Blood Flow and LDL Transport in a Porohyperelastic Arterial Wall Model
J Biomech Eng. June 2007, 129(3): 374–385.
doi: https://doi.org/10.1115/1.2720914
Topics:
Blood flow
,
Deformation
,
Filtration
,
Flow (Dynamics)
,
Fluid structure interaction
,
Porous materials
,
Pulsatile flow
,
Displacement
,
Simulation
,
Blood
Joint/Whole Body
Effect of ACL Deficiency on MCL Strains and Joint Kinematics
J Biomech Eng. June 2007, 129(3): 386–392.
doi: https://doi.org/10.1115/1.2720915
Topics:
Anterior cruciate ligament
,
Kinematics
,
Knee
,
Rotation
,
Fibers
,
Testing
Determining Fall Direction and Impact Location for Various Disturbances and Gait Speeds Using the Articulated Total Body Model
J Biomech Eng. June 2007, 129(3): 393–399.
doi: https://doi.org/10.1115/1.2737432
Topics:
Hip fractures
,
Sensitivity analysis
,
Simulation
Soft Tissue
Long Durations of Immobilization in the Rat Result in Enhanced Mechanical Properties of the Healing Supraspinatus Tendon Insertion Site
J Biomech Eng. June 2007, 129(3): 400–404.
doi: https://doi.org/10.1115/1.2721075
Topics:
Biological tissues
,
Bone
,
Maintenance
,
Mechanical properties
,
Tendons
,
Failure
,
Biomechanics
,
Elasticity
,
Stiffness
Equivalence Between Short-Time Biphasic and Incompressible Elastic Material Responses
J Biomech Eng. June 2007, 129(3): 405–412.
doi: https://doi.org/10.1115/1.2720918
Topics:
Biological tissues
,
Compression
,
Constitutive equations
,
Deformation
,
Elasticity
,
Finite element analysis
,
Permeability
,
Stress
,
Tensors
,
Tension
Extraction of Mechanical Properties of Articular Cartilage From Osmotic Swelling Behavior Monitored Using High Frequency Ultrasound
J Biomech Eng. June 2007, 129(3): 413–422.
doi: https://doi.org/10.1115/1.2720919
Topics:
Cartilage
,
Ultrasound
,
Bone
,
Biological tissues
,
Mechanical properties
Effects of Tension-Compression Nonlinearity on Solute Transport in Charged Hydrated Fibrous Tissues Under Dynamic Unconfined Compression
J Biomech Eng. June 2007, 129(3): 423–429.
doi: https://doi.org/10.1115/1.2720920
Topics:
Biological tissues
,
Cartilage
,
Compression
,
Convection
,
Tension
,
Desorption
,
Diffusion (Physics)
,
Dynamic testing (Materials)
Robust Strategies for Automated AFM Force Curve Analysis—I. Non-adhesive Indentation of Soft, Inhomogeneous Materials
J Biomech Eng. June 2007, 129(3): 430–440.
doi: https://doi.org/10.1115/1.2720924
Topics:
Atomic force microscopy
,
Contact mechanics
,
Elasticity
,
Young's modulus
,
Cartilage
,
Fittings
,
Algorithms
,
Adhesives
Computational Model for the Transition From Peristaltic to Pulsatile Flow in the Embryonic Heart Tube
J Biomech Eng. June 2007, 129(3): 441–449.
doi: https://doi.org/10.1115/1.2721076
Topics:
Flow (Dynamics)
,
Outflow
,
Pressure
,
Pulsatile flow
,
Waves
,
Blood
,
Wavelength
,
Valves
,
Inflow
,
Physiology
The Nonlinear Material Properties of Liver Tissue Determined From No-Slip Uniaxial Compression Experiments
J Biomech Eng. June 2007, 129(3): 450–456.
doi: https://doi.org/10.1115/1.2720928
Topics:
Biological tissues
,
Compression
,
Liver
,
Stress
,
Friction
,
Materials properties
A Lagrange Multiplier Mixed Finite Element Formulation for Three-Dimensional Contact of Biphasic Tissues
J Biomech Eng. June 2007, 129(3): 457–471.
doi: https://doi.org/10.1115/1.2737056
Topics:
Biological tissues
,
Finite element analysis
,
Pressure
,
Fluids
,
Traction
,
Bone
,
Cartilage
,
Displacement