The efficiency of a cooled turbine stage has been discussed in the literature. All proposed definitions compare the actual power output with an ideal output, which has to be determined; but usually, one of two definitions has been used by turbine designers. In the first, the so-called Hartsel efficiency, the mainstream gas flow, and the various coolant flows to rotor and stator are assumed to expand separately and isentropically to the backpressure. In the second, it is assumed that these flows mix at constant (mainstream) gas pressure before expanding isentropically (sometimes, the rotor coolant flow is ignored in this definition). More recently, it has been suggested that a thermodynamically sounder definition is one in which the gas and coolant flows mix reversibly and adiabatically before isentropic expansion to the backpressure. In the current paper, these three efficiencies are compared, for a typical stage—the first cooled stage of a multistage industrial gas turbine. It is shown that all the efficiencies fall more or less linearly with increase of the fractional (total) coolant flow. It is also shown that the new definition of efficiency gives values considerably lower than the other two efficiencies, which are more widely used at present. Finally, the various irreversibilities associated with the flow through a cooled turbine are calculated. Although all these irreversibilities increase with the fractional coolant flow, it is shown that the “thermal” irreversibility associated with film cooling is higher than the other irreversibilities at large fractional coolant flow.
Skip Nav Destination
Article navigation
January 2008
Research Papers
Calculations of Cooled Turbine Efficiency
J. H. Horlock,
J. H. Horlock
Whittle Laboratory,
University of Cambridge
, Cambridge, CB3 0DY, UK
Search for other works by this author on:
Leonardo Torbidoni
Leonardo Torbidoni
Search for other works by this author on:
J. H. Horlock
Whittle Laboratory,
University of Cambridge
, Cambridge, CB3 0DY, UK
Leonardo Torbidoni
J. Eng. Gas Turbines Power. Jan 2008, 130(1): 011703 (5 pages)
Published Online: January 11, 2008
Article history
Received:
July 5, 2006
Revised:
August 9, 2006
Published:
January 11, 2008
Citation
Horlock, J. H., and Torbidoni, L. (January 11, 2008). "Calculations of Cooled Turbine Efficiency." ASME. J. Eng. Gas Turbines Power. January 2008; 130(1): 011703. https://doi.org/10.1115/1.2771250
Download citation file:
Get Email Alerts
An Experimental Comparison of Methanol Combustion Strategies: Spark Ignition Versus Compression Ignition
J. Eng. Gas Turbines Power
Systems-Based Approach To Predicting Tbc Delamination Due To Cmas Infiltration
J. Eng. Gas Turbines Power
Related Articles
Calculation of the Expansion Through a Cooled Gas Turbine Stage
J. Turbomach (July,2006)
Estimating the Loss Associated With Film Cooling for a Turbine Stage
J. Turbomach (March,2012)
Defining the Efficiency of a Cooled Turbine
J. Turbomach (October,2006)
Film-Cooling Effectiveness on a Rotating Turbine Platform Using Pressure Sensitive Paint Technique
J. Turbomach (October,2010)
Related Chapters
Thermodynamic Performance
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Control and Operational Performance
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
The Special Characteristics of Closed-Cycle Gas Turbines
Closed-Cycle Gas Turbines: Operating Experience and Future Potential