In this article, the design and development of a real-time heart rate (HR) and respiratory rate (RR) monitoring device is reported. The proposed device is designed to impose minimum data acquisition hazards on the subject. In standard bedside monitors, HR and RR are derived from electrocardiogram (ECG) and respiration signals, respectively, and different electrodes are required for capturing the 12-lead ECG and respiration via a chest belt, which is cumbersome for patients and healthcare providers. Respiration signal has an impact on ECG due to anatomical proximity of the heart and lung, and ECG is modulated by respiration, a phenomenon known as respiratory sinus arrhythmia (RSA). In the proposed method, the ECG signal is acquired using clip electrodes at the wrists and the respiration signal is extracted from the ECG using an Arduino Uno microcontroller-based real-time processing of ECG. RR is then derived from ECG-derived respiration (EDR). The prototype is tested on healthy subjects and compared to measurements taken using a standard MP45 data acquisition device associated with a Biopac Student Lab (BSL). A mean percentage error of 5.54 ± 8.48% was observed under normal breathing conditions and an error of −3.41 ± 3.27% was observed for a single subject tested under a variety of breathing conditions, such as resting, stair-climbing, and paced breathing. The proposed algorithm can also be used in combination with standard ECG monitoring systems to measure HR and RR, without any data acquisition hazard to the subject.

References

1.
Fieselmann
,
J. F.
,
Hendryx
,
M. S.
,
Helms
,
C. M.
, and
Wakefield
,
D. S.
,
1993
, “
Respiratory Rate Predicts Cardiopulmonary Arrest for Internal Medicine Inpatients
,”
J. Gen. Intern. Med.
,
8
(
7
), pp.
354
360
.
2.
Cretikos
,
M.
,
Chen
,
J.
,
Hillman
,
K.
,
Bellomo
,
R.
,
Finfer
,
S.
,
Flabouris
,
A.
, and
Merit Study Investigators
,
2007
, “
The Objective Medical Emergency Team Activation Criteria: A Case–Control Study
,”
Resuscitation
,
73
(
1
), pp.
62
72
.
3.
Cretikos
,
M. A.
,
Bellomo
,
R.
,
Hillman
,
K.
,
Chen
,
J.
,
Finfer
,
S.
, and
Flabouris
,
A.
,
2008
, “
Respiratory Rate: The Neglected Vital Sign
,”
Med. J. Aust.
,
188
(
11
), pp.
657
659
.
4.
Elliott
,
M.
, and
Coventry
,
A.
,
2012
, “
Critical Care: The Eight Vital Signs of Patient Monitoring
,”
Br. J. Nurs.
,
21
(
10
), pp.
621
625
.
5.
Mitchell
,
I.
, and
Van Leuvan
,
C. H.
,
2008
, “
Missed Opportunities? An Observational Study of Vital Sign Measurements
,”
Crit. Care Resusc.
,
10
(
2
), pp.
111
115
.
6.
Moody
,
G. B.
,
Mark
,
R. G.
,
Zoccola
,
A.
, and
Mantero
,
S.
, 1985, “
Derivation of Respiratory Signals From Multi-Lead ECGs
,” Comput. Cardiol.,
12
, pp. 113–116.
7.
Caggiano
,
D.
, and
Reisman
,
S.
,
1996
, “
Respiration Derived From the Electrocardiogram: A Quantitative Comparison of Three Different Methods
,”
IEEE
22nd Annual Northeast Bioengineering Conference, New Brunswick, NJ, Mar. 14–15, pp. 103–104.
8.
Zhao
,
L.
,
Reisman
,
S.
, and
Findley
,
T.
,
1994
, “
Respiration Derived From the Electrocardiogram During Heart Rate Variability Studies
,” 16th Annual International Conference of
IEEE
Engineering in Medicine and Biology Society, Baltimore, MD, Nov. 3–6, pp.
123
124
.
9.
Behbehani
,
K.
,
Vijendra
,
S.
,
Burk
,
J. R.
, and
Lucas
,
E. A.
,
2002
, “
An Investigation of the Mean Electrical Axis Angle and Respiration During Sleep
,” 24th Annual International Conference of
IEEE
Engineering in Medicine and Biology Society, Houston, TX, Oct. 23–26, Vol. 2, pp.
1550
1551
.
10.
Khaled
,
Z. B.
, and
Farges
,
G.
,
1992
, “
First Approach for Respiratory Monitoring by Amplitude Demodulation of the Electrocardiogram
,” 14th Annual International Conference of
IEEE
Engineering in Medicine and Biology Society, Paris, NJ, Oct. 29–Nov. 1, Vol. 6, pp.
2535
2536
.
11.
Dobrev
,
D.
, and
Daskalov
,
I.
,
1999
, “
Two-Electrode Telemetric Instrument for Infant Heart Rate and Apnea Monitoring
,”
Med. Eng. Phys.
,
20
(
10
), pp.
729
734
.
12.
Mason
,
C. L.
, and
Tarassenko
,
L.
,
2001
, “
Quantitative Assessment of Respiratory Derivation Algorithms
,” 23rd Annual International Conference of the
IEEE
Engineering in Medicine and Biology Society, Istanbul, Turkey, Oct. 25–28, Vol.
2
, pp.
1998
2001
.
13.
De Chazal
,
P.
,
Heneghan
,
C.
,
Sheridan
,
E.
,
Reilly
,
R.
,
Nolan
,
P.
, and
O'Malley
,
M.
,
2003
, “
Automated Processing of the Single-Lead Electrocardiogram for the Detection of Obstructive Sleep Apnoea
,”
IEEE Trans. Biomed. Eng.
,
50
(
6
), pp.
686
696
.
14.
O'Brien
,
C.
, and
Heneghan
,
C.
,
2007
, “
A Comparison of Algorithms for Estimation of a Respiratory Signal From the Surface Electrocardiogram
,”
Comput. Biol. Med.
,
37
(
3
), pp.
305
314
.
15.
Womack
,
B. F.
,
1971
, “
The Analysis of Respiratory Sinus Arrhythmia Using Spectral Analysis and Digital Filtering
,”
IEEE Trans. Biomed. Eng.
,
18
(
6
), pp.
399
409
.
16.
Ahmad
,
S.
,
Batkin
,
I.
,
Kelly
,
O.
,
Bolic
,
M.
,
Groza
,
V.
, and
Dajani
,
H. R.
,
2013
, “
Electrocardiogram-Derived Respiration Using Dynamic Filter Coefficients
,”
Trans. Jap. Soc. Med. Biol. Eng.
,
51
(S), p. M-143.
17.
Keissar
,
K.
,
Davrath
,
L. R.
, and
Akselrod
,
S.
,
2009
, “
Coherence Analysis Between Respiration and Heart Rate Variability Using Continuous Wavelet Transform
,”
Philos. Trans. R. Soc., A
,
367
(
1892
), pp.
1393
1406
.
18.
Zensorium,
2014
, “
Comparison of Tinké (Lightning) to Masimo (Rad-5) Pulse Oximeter at Normal SpO2 Levels
,”
Zensorium
, Singapore.
19.
Kim
,
J.-H.
,
Roberge
,
R.
,
Powell
,
J. B.
,
Shafer
,
A. B.
, and
Williams
,
W. J.
,
2013
, “
Measurement Accuracy of Heart Rate and Respiratory Rate During Graded Exercise and Sustained Exercise in the Heat Using the Zephyr BioHarnessTM
,”
Int. J. Sports Med.
,
34
(
6
), pp.
497
501
.
20.
Pan
,
J.
, and
Tompkins
,
W. J.
,
1985
, “
A Real-Time QRS Detection Algorithm
,”
IEEE Trans. Biomed. Eng.
,
32
(
3
), pp.
230
236
.
21.
Abramowitz
,
M.
, and
Stegun
,
I. A.
,
1974
,
Handbook of Mathematical Functions, With Formulas, Graphs, and Mathematical Tables
,
Dover Publications
,
Mineola, NY
.
22.
Shen
,
W.
,
2015
,
An Introduction to Numerical Computation
,
World Scientific Publishing
,
Singapore
.
23.
Pflanzer
,
R.
, and
McMullen
,
W.
,
2014
, “
Respiratory Cycle I Procedure. Biopac Student Lab Manual
,” BIOPAC Systems, Inc., Goleta, CA.
You do not currently have access to this content.