This paper describes the initial design and optimization of a compliant endoscopic suturing instrument. The emerging field of Natural Orifice Transluminal Endoscopic Surgery (NOTES) requires innovative instruments to meet the size limitations inherent in this type of minimally invasive surgery; using compliant mechanisms is proposed as one method of meeting this requirement. The compliant design was modeled and optimized to maximize the distal opening and provide a puncture force of at least 4.6N, while being small enough to fit within a 3.3mm working channel. The design utilizes contact for stress relief and intertwining parts for added deflection. ANSYS® was used for finite element analysis including contact and nonlinear deformations. A prototype was fabricated from the optimized geometry and experimentally tested. The best geometry is predicted to have a distal opening of 14.6mm at the tips and supply a puncturing force of 4.83N. The force supplied at the tip was measured and was found to exceed the required 4.6N. The prototype successfully passed two complete sutures and qualitative results are provided. The results of the study will lead to further refinements and improvements in future designs.

1.
Rattner
,
D.
, and
Hawes
,
R. H.
, 2006, “
NOTES: Gathering Momentum
,”
Surg. Endosc
0930-2794,
20
(
5
), pp.
711
712
.
2.
Wallace
,
M.
, 2006, “
Take NOTES (Natural Orifice Transluminal Endoscopic Surgery)
,”
Gastroenterology
0016-5085,
131
(
1
), pp.
11
12
.
3.
Rattner
,
D.
, 2006, “
ASGE/SAGES Working Group on Natural Orifice Translumenal Endoscopic Surgery-October 2005
,”
Surg. Endosc
0930-2794,
20
(
2
), pp.
329
333
.
4.
Richards
,
W. O.
, and
Rattner
,
D. W.
, 2005, “
Endoluminal and Transluminal Surgery—No Longer If, But When
,”
Surg. Endosc
0930-2794,
19
(
4
), pp.
461
463
.
5.
Chuttani
,
R.
,
Barkun
,
A.
,
Carpenter
,
S.
,
Chotiprasidhi
,
P.
,
Ginsberg
,
G. G.
,
Hussain
,
N.
,
Liu
,
J.
,
Silverman
,
W.
,
Taitelbaum
,
G.
, and
Petersen
,
B.
, 2006, “
Endoscopic Clip Application Devices
,”
Gastrointest. Endosc.
0016-5107,
63
(
6
), pp.
746
750
.
6.
Malik
,
A.
,
Mellinger
,
J. D.
,
Hazey
,
J. W.
,
Dunkin
,
B. J.
, and
MacFadyen
,
B. V.
, Jr.
, 2006, “
Endoluminal and Transluminal Surgery: Current Status and Future Possibilities
,”
Surg. Endosc
0930-2794,
20
(
8
), pp.
1179
1192
.
7.
Croce
,
E.
, and
Olmi
,
S.
, 1997, “
Extracorporeal Knotting Simplified With a New Instrument
,”
Surg. Endosc
0930-2794,
11
(
9
), pp.
963
964
.
8.
Park
,
P. O.
,
Bergstroem
,
M.
,
Ikeda
,
K.
,
Fritscher-Ravens
,
A.
, and
Swain
,
P.
, 2005, “
Experimental Studies of Transgastric Gallbladder Surgery: Cholecystectomy and Cholecystogastric Anastomosis (Videos)
,”
Gastrointest. Endosc.
0016-5107,
61
(
4
), pp.
601
606
.
9.
Fritscher-Ravens
,
A.
,
Mosse
,
C. A.
,
Mills
,
T. N.
,
Mukherjee
,
D.
,
Park
,
P. O.
, and
Swain
,
P.
, 2002, “
A Through-the-Scope Device for Suturing and Tissue Approximation Under EUS Control
,”
Gastrointest. Endosc.
0016-5107,
56
(
5
), pp.
737
742
.
10.
Sclabas
,
G. M.
,
Swain
,
P.
, and
Swanstrom
,
L. L.
, 2006, “
Endoluminal Methods for Gastrotomy Closure in Natural Orifice TransEnteric Surgery (NOTES)
,”
Surgical Innovation
,
13
(
1
), pp.
23
30
.
11.
Dubrowski
,
A.
,
Sidhu
,
R.
,
Park
,
J.
, and
Carnahan
,
H.
, 2005, “
Quantification of Motion Characteristics and Forces Applied to Tissues During Suturing
,”
Am. J. Surg.
0002-9610,
190
(
1
), pp.
131
136
.
12.
Wagh
,
M.
,
Merrifield
,
B.
, and
Thompson
,
C. C.
, 2006, “
Survival Studies After Endoscopic Transgastric Oophorectomy and Tubectomy in a Porcine Model
,”
Gastrointest. Endosc.
0016-5107,
63
(
3
), pp.
473
478
.
13.
Pai
,
R.
, 2006, “
Transcolonic Endoscopic Cholecystectomy: A NOTES Survival Study in a Porcine Model
,”
Gastrointest. Endosc.
0016-5107,
64
(
3
), pp.
428
434
.
14.
Hu
,
B.
,
Chung
,
S. S. C.
,
Sun
,
L. C. L.
,
Kawashima
,
K.
,
Yamamoto
,
T.
,
Cotton
,
P. B.
,
Gostout
,
C. J.
,
Hawes
,
R. H.
,
Kalloo
,
A. N.
,
Kantsevoy
,
S. V.
, and
Pasricha
,
P. J.
, 2005, “
Transoral Obesity Surgery: Endoluminal Gastroplasty With an Endoscopic Suture Device
,”
Endoscopy
0013-726X,
37
(
5
), pp.
411
414
.
15.
Bergstrom
,
M.
,
Ikeda
,
K.
,
Swain
,
P.
, and
Park
,
P. O.
, 2006, “
Transgastric Anastomosis by Using Flexible Endoscopy in a Porcine Model (With Video)
,”
Gastrointest. Endosc.
0016-5107,
63
(
2
), pp.
307
312
.
16.
Szabo
,
Z.
, 1993, “
Laparoscopic Suturing and Tissue Approximation
,”
Minimally Invasive Surgery
,
J. G.
Hunter
and
J. M.
Sackier
, eds.,
McGraw-Hill
,
New York
, pp.
3
6
.
17.
Kortenbach
,
J. A.
,
Sixto
,
R.
, Jr.
, and
McBrayer
,
M. S.
, 1998, “
Automatic Needle-Passer Suturing Instrument
,” U.S. Patent No. 5,814,0543.
18.
Nolan
,
P.
,
Tovey
,
H. J.
,
Stone
,
C. W.
, and
Gardner
,
G. S.
, 1996, “
Method of Employing Surgical Suturing Apparatus to Tie Knots
,” U.S. Patent No. 5,480,406.
19.
Luharuka
,
R.
, and
Hesketh
,
P. J.
, 2007, “
Design of fully Compliant, In-Plane Rotary, Bistable Micromechanisms for MEMS Applications
,”
Sens. Actuators, A
0924-4247,
134
(
1
), pp.
231
238
.
20.
Howell
,
L. L.
, 2001,
Compliant Mechanisms
,
Wiley
,
New York
.
21.
Kota
,
S.
,
Ananthasuresh
,
G.
,
Crary
,
S. B.
, and
Wise
,
K. D.
, 1994, “
Design and Fabrication of Microelectromechanical Systems
,”
ASME J. Mech. Des.
1050-0472,
116
(
4
), pp.
1081
1088
.
22.
Frecker
,
M.
, 1999, “
Topology Optimization of Compliant Mechanisms With Multiple Outputs
,”
Struct. Optim.
0934-4373,
17
(
4
), pp.
269
278
.
23.
Frecker
,
M. I.
,
Powell
,
K. M.
, and
Haluck
,
R. S.
, 2005, “
Design of a Multifunctional Compliant Instrument for Minimally Invasive Surgery
,”
ASME J. Biomech. Eng.
0148-0731,
127
(
6
), pp.
990
993
.
24.
Lu
,
K. J.
, and
Kota
,
S.
, 2006, “
Topology and Dimensional Synthesis of Compliant Mechanisms Using Discrete Optimization
,”
ASME J. Mech. Des.
1050-0472,
128
(
5
), pp.
1080
1091
.
25.
Dutch Ophthalmic Research, C.
, 2006, “
Claes Combination Straight Microscissors/Forceps
,” www.dorc.nlwww.dorc.nl, Aug. 2006.
26.
Alcon
, 2006, “
Eye Health Information From Alcon
,” www.alcon.comwww.alcon.com, Aug. 2006.
27.
Kantsevoy
,
S. V.
,
Niiyama
,
H.
,
Jagannath
,
S. B.
,
Chung
,
S. S. C.
,
Cotton
,
P. B.
,
Gostout
,
C. J.
,
Hawes
,
R. H.
,
Pasricha
,
P. J.
,
Magee
,
C. A.
,
Vaughn
,
C. A.
,
Barlow
,
D.
,
Kawano
,
H.
,
Shimonaka
,
H.
, and
Kalloo
,
A. N.
, 2006, “
The Endoscopic Transilluminator: An Endoscopic Device for Identification of the Proximal Jejunum for Transgastric Endoscopic Gastrojejunostomy
,”
Gastrointest. Endosc.
0016-5107,
63
(
7
), pp.
1055
1058
.
28.
Kantsevoy
,
S. V.
,
Jagannath
,
S. B.
,
Niiyama
,
H.
,
Chung
,
S. S. C.
,
Cotton
,
P. B.
,
Gostout
,
C. J.
,
Hawes
,
R. H.
,
Pasricha
,
P. J.
,
Magee
,
C. A.
,
Vaughn
,
C. A.
,
Barlow
,
D.
,
Shimonaka
,
H.
, and
Kalloo
,
A. N.
, 2005, “
Endoscopic Gastrojejunostomy With Survival in a Porcine Model
,”
Gastrointest. Endosc.
0016-5107,
62
(
2
), pp.
287
292
.
29.
Kalloo
,
A.
,
Singh
,
V. K.
,
Jagannath
,
S. B.
,
Niiyama
,
H.
,
Hill
,
S. L.
,
Vaughn
,
C. A.
,
Magee
,
C. A.
, and
Kantsevoy
,
S. V.
, 2004, “
Flexible Transgastric Peritoneoscopy: A Novel Approach to Diagnostic and Therapeutic Interventions in the Peritoneal Cavity
,”
Gastrointest. Endosc.
0016-5107,
60
(
1
), pp.
114
117
.
30.
Sumiyama
,
K.
,
Gostout
,
C. J.
,
Rajan
,
E.
,
Bakkan
,
T. A.
,
Deters
,
J. L.
,
Knipschield
,
M. A.
,
Hawes
,
R. H.
,
Kalloo
,
A. N.
,
Pasricha
,
P. J.
,
Chung
,
S. S. C.
,
Kantsevoy
,
S. V.
, and
Cotton
,
P. B.
, 2006, “
Pilot Study of the Porcine Uterine Horn as an In Vivo Appendicitis Model for Development of Endoscopic Transgastric Appendectomy
,”
Gastrointest. Endosc.
0016-5107,
64
(
5
), pp.
808
812
.
31.
Jagannath
,
S.
,
Kantsevoy
,
S. V.
,
Vaughn
,
C. A.
,
Chung
,
S. S. C.
,
Cotton
,
P. B.
,
Gostout
,
C. J.
,
Hawes
,
R. H.
,
Pasricha
,
P. J.
,
Scorpio
,
D. G.
,
Magee
,
C. A.
,
Pipitone
,
L. J.
, and
Kalloo
,
A. N.
, 2005, “
Peroral Transgastric Endoscopic Ligation of Fallopian Tubes With Long-Term Survival in a Porcine Model
,”
Gastrointest. Endosc.
0016-5107,
61
(
3
), pp.
449
453
.
32.
Awan
,
A.
, and
Swain
,
P.
, 2002, “
Endoscopic Vertical Band Gastroplasty With an Endoscopic Sewing Machine
,”
Gastrointest. Endosc.
0016-5107,
55
(
2
), pp.
254
256
.
33.
Chiu
,
P. W. Y.
,
Hu
,
B.
,
Lau
,
J. Y. W.
,
Sun
,
L. C. L.
,
Sung
,
J. J. Y.
, and
Chung
,
S. S. C.
, 2006, “
Endoscopic Plication of Massively Bleeding Peptic Ulcer by Using the Eagle Claw VII Device: A Feasibility Study in a Porcine Model
,”
Gastrointest. Endosc.
0016-5107,
63
(
4
), pp.
681
685
.
34.
Rajan
,
E.
,
Gostout
,
C. J.
,
Burgart
,
L. J.
,
Leontovich
,
O. N.
,
Knipschield
,
M. A.
,
Herman
,
L. J.
, and
Norton
,
I. D.
, 2002, “
First Endoluminal System for Transmural Resection of Colorectal Tissue With a Prototype Full-Thickness Resection Device in a Porcine Model
,”
Gastrointest. Endosc.
0016-5107,
55
(
7
), pp.
915
920
.
35.
Chen
,
Y.
, 2005, “
Endoscopic Suturing Devices for Treatment of GERD: Too Little, Too Late?
,”
Gastrointest. Endosc.
0016-5107,
62
(
1
), pp.
44
47
.
36.
Schilling
,
D.
,
Kiesslich
,
R.
,
Galle
,
P. R.
, and
Riemann
,
J. F.
, 2005, “
Endoluminal Therapy of GERD With a New Endoscopic Suturing Device
,”
Gastrointest. Endosc.
0016-5107,
62
(
1
), pp.
37
43
.
37.
Pham
,
B.
,
Raju
,
G. S.
,
Ahmed
,
I.
,
Brining
,
D.
,
Chung
,
S. S. C.
,
Cotton
,
P. B.
,
Gostout
,
C. J.
,
Hawes
,
R. H.
,
Kalloo
,
A. N.
,
Kantsevoy
,
S. V.
, and
Pasricha
,
P. J.
, 2006, “
Immediate Endoscopic Closure of Colon Perforation by Using a Prototype Endoscopic Suturing Device: Feasibility and Outcome in a Porcine Model (With Video)
,”
Gastrointest. Endosc.
0016-5107,
64
(
1
), pp.
113
119
.
38.
Sumiyama
,
K.
,
Gostout
,
C. J.
,
Rajan
,
E.
,
Bakkan
,
T. A.
,
Deters
,
J. L.
, and
Knipschield
,
M. A.
, 2007, “
Endoscopic Full-Thickness Closure of Large Gastric Perforations by Use of Tissue Anchors
,”
Gastrointest. Endosc.
0016-5107,
65
(
1
), pp.
134
139
.
39.
Tuebergen
,
D.
,
Rijcken
,
E.
, and
Senninger
,
N.
, 2004, “
Esophageal Perforation as a Complication of EndoCinch Endoluminal Gastroplication
,”
Endoscopy
0013-726X,
36
(
7
), pp.
663
665
.
40.
Aggarwal
,
R.
, 2006, “
Training Junior Operative Residents in Laparoscopic Suturing Skills is Feasible and Efficacious
,”
Surgery (St. Louis)
0039-6060,
139
(
6
), pp.
729
734
.
41.
Lieberman
,
D.
,
De Garmo
,
P. L.
,
Fleischer
,
D. E.
,
Eisen
,
G. M.
, and
Helfand
,
M.
, 2000, “
Patterns of Endoscopy Use in the United States
,”
Gastroenterology
0016-5085,
118
(
3
), pp.
619
624
.
42.
Talamini
,
M.
, and
Hanly
,
E. J.
, 2005, “
Technology in the Operating Suite
,”
JAMA, J. Am. Med. Assoc.
0098-7484,
293
(
7
), pp.
863
866
.
43.
Sivak
,
M.
, 2004, “
Polypectomy: Looking Back
,”
Gastrointest. Endosc.
0016-5107,
60
(
6
), pp.
977
982
.
44.
Vitale
,
G. C.
,
Davis
,
B. R.
, and
Tran
,
T. C.
, 2005, “
The Advancing Art and Science of Endoscopy
,”
Am. J. Surg.
0002-9610,
190
(
2
), pp.
228
233
.
45.
Lyons
,
T. L.
, and
Winer
,
W. K.
, 2005, “
An Innovative Bipolar Instrument for Laparoscopic Surgery
,”
J. Soc. Laparoendosc Surg.
1086-8089,
9
, pp.
39
41
.
46.
Berguer
,
R.
, 1998, “
Surgical Technology and the Ergonomics of Laparoscopic Instruments
,”
Surg. Endosc
0930-2794,
12
(
5
), pp.
458
462
.
47.
Sastry
,
S. S.
,
Cohn
,
M.
, and
Tendick
,
F.
, 1997, “
Milli-Robotics for Remote, Minimally Invasive Surgery
,”
Rob. Auton. Syst.
0921-8890,
21
(
3
), pp.
305
316
.
48.
Drake
,
C.
, 1997, “
Virtual Endoscopy Lets Physicians ‘Fly Through’ Procedures
,” The BBI Newsletter, Vol.
2006
, http://www.findarticles.com/p/articles/mi_m3570/is_n5_v20/ai_19524879/http://www.findarticles.com/p/articles/mi_m3570/is_n5_v20/ai_19524879/, Aug. 2006.
49.
Schultz
,
L. S.
, and
Poppe
,
K.
, 1997, “
Using 5-mm Bipolar Cutting Forceps: A New Multifunctional Instrument
,”
J. Laparoendosc Adv. Surg. Tech. A
1092-6429,
7
(
6
), pp.
375
378
.
50.
Mahmood
,
Z.
,
McMahon
,
B. P.
,
Arfin
,
Q.
,
Byrne
,
P. J.
,
Reynolds
,
J. V.
,
Murphy
,
E. M.
, and
Weir
,
D. G.
, 2003, “
Endocinch therapy for Gastro-Oesophageal Reflux Disease: A One Year Prospective Follow Up
,”
Gut
0017-5749,
52
(
1
), pp.
34
39
.
51.
Bisgaard
,
T.
,
Klarskov
,
B.
,
Rosenberg
,
J.
, and
Kehlet
,
H.
, 2001, “
Factors Determining Convalescence After Uncomplicated Laparoscopic Cholecystectomy
,”
Arch. Surg. (Chicago)
0004-0010,
136
(
8
), pp.
917
921
.
52.
Ponsky
,
J.
, 2005, “
Gastroenterologists as Surgeons: What They Need to Know
,”
Gastrointest. Endosc.
0016-5107,
61
(
3
), p.
454
.
53.
Cuschieri
,
A.
,
Shimi
,
S.
,
Banting
,
S.
, and
Velpen
,
G. V.
, 1993, “
Endoscopic Ultrasonic Dissection for Thoracoscopic and Laparoscopic Surgery
,”
Surg. Endosc
0930-2794,
7
(
3
), pp.
197
199
.
54.
Wood
,
W.
, 2005, “
The Times–They Are A-Changin
,”
Am. Surg.
0003-1348,
71
(
6
), pp.
461
465
.
55.
Jones
,
D. B.
, and
Soper
,
N. J.
, 1994, “
Laparoscopic General-Surgery–Current Status and Future Potential
,”
AJR, Am. J. Roentgenol.
0361-803X,
163
(
6
), pp.
1295
1301
.
56.
Hochberger
,
J.
, and
Lamade
,
W.
, 2005, “
Transgastric Surgery in the Abdomen: The Dawn of a New Era?
,”
Gastrointest. Endosc.
0016-5107,
62
(
2
), pp.
293
296
.
57.
Hunter
,
J. G.
, and
Sackier
,
J. M.
, 1993, “
Minimally Invasive High Tech Surgery: Into the 21st Century
,”
Minimally Invasive Surgery
,
J. G.
Hunter
and
J. M.
Sackier
, eds.,
McGraw-Hill
,
New York
, pp.
3
6
.
58.
Ball
,
K. A.
, 1997,
Endoscopic Surgery
,
Mosby
,
Philadelphia
.
59.
Richard Wolf Medical Instruments, C.
, 2007, “
Endoscopes: Care and Handling
,” Vol.
2007
.
60.
Olympus Europa, G.
, 2003, “
Endoscope Overview 2003/2004
.”
61.
Hu
,
B.
, 2005, “
Eagle Claw II: A Novel Endosuture Device That Uses a Curved Needle for Major Arterial Bleeding: A Bench Study
,”
Gastrointest. Endosc.
0016-5107,
62
(
2
), pp.
266
270
.
62.
Chuttani
,
R.
, 2002, “
A Novel Endoscopic Full-Thickness Plicator for Treatment of GERD: An Animal Model Study
,”
Gastrointest. Endosc.
0016-5107,
56
(
1
), pp.
116
122
.
63.
Hu
,
B.
,
Chung
,
S. S. C.
,
Sun
,
L. C. L.
,
Lau
,
J. Y. W.
,
Kawashima
,
K.
,
Yamamoto
,
T.
,
Cotton
,
P. B.
,
Gostout
,
C. J.
,
Hawes
,
R. H.
,
Kalloo
,
A. N.
,
Kantsevoy
,
S. V.
, and
Pasricha
,
P. J.
, 2005, “
Endoscopic Suturing Without Extracorporeal Knots: A Laboratory Study
,”
Gastrointest. Endosc.
0016-5107,
62
(
2
), pp.
230
233
.
64.
Ikeda
,
K.
,
Fritscher-Ravens
,
A.
,
Mosse
,
C. A.
,
Mills
,
T. N.
,
Tajiri
,
H.
, and
Swain
,
P.
, 2005, “
Endoscopic Full-Thickness Resection With Sutured Closure in a Porcine Model
,”
Gastrointest. Endosc.
0016-5107,
62
(
1
), pp.
122
129
.
65.
Aguirre
,
M.
, and
Frecker
,
M.
, 2007, “
Size and Shape Optimization of a 1.0mm Multifunctional Forceps-Scissors Surgical Instrument
,”
ASME J. Med. Devices
1932-6181,
2
(
1
), p.
015001
.
66.
Frecker
,
M.
,
Dziedic
,
R.
, and
Haluck
,
R. S.
, 2002, “
Design of Multifunctional Compliant Mechanisms for Minimally Invasive Surgery
,”
Minimally Invasive Ther. Allied Technol.
1364-5706,
11
(
5–6
), pp.
311
319
.
67.
Culkar
,
K.
, 2004, “
Design and Optimization of Minimally Invasive Multifunctional Surgical Instruments
,”
Honors
, Mechanical Engineering, Penn State University, State College.
68.
Sauer
,
J. S.
,
Fitzsimmons
,
M. W.
, and
Bovard
,
M. A.
, 2006, “
System for Endoscopic Suturing
,” U.S. Patent No. 6,997,931.
69.
Cronin
,
S.
,
Frecker
,
M. I.
, and
Mathew
,
A.
, 2007, “
Puncture Force Measurements on a Porcine Stomach
,”
Gastrointest. Endosc.
0016-5107,
65
(
5
), p.
AB294
.
70.
Cronin
,
J.
,
Frecker
,
M.
, and
Mathew
,
A.
, 2007, “
Design of a Compliant Endoscopic Suturing Instrument
,”
Proceedings of the IDETC/CIE 2007 Conference
, Sept. 4–7,
Las Vegas, NV
.
You do not currently have access to this content.