Natural orifice translumenal endoscopic surgery (NOTES) is a relatively new surgical approach that uses no external incisions, thereby improving cosmetic outcomes, decreasing overall recovery time, and reducing the risk of external infection. In standard NOTES, flexible endoscopic tools have been used to carry out a variety of surgical procedures in the abdomen. As an alternative, miniature in vivo robots can be fully inserted into the peritoneal cavity and utilized to perform various surgical procedures. These in vivo robots eliminate tool triangulation issues, improve multitasking capabilities, and greatly increase freedom and dexterity when compared to standard endoscopic and laparoscopic tools. One major limitation is that once inserted, the in vivo robots are isolated within the abdomen and cannot send or receive materials to the external environment. The topic of this paper is a material handling system that has been developed to bridge this deficiency. This system features a flexible silicone overtube and an open-loop control system with manual and automatic operation capabilities. The system utilizes the helix of a spring to advance a payload (staples, robotic tool tips, etc.) along the length of the overtube. The system functioned as intended in benchtop and in vivo testing. Minimum bend radius was identified, and a payload was successfully advanced and retrieved through the shuttling system in porcine surgical procedures. NOTES access was achieved via a custom built transvaginal trocar. This paper presents the design and rationale, control strategy, and in vivo testing results for the NOTES material handling system. The system performs as intended based on functional requirements as demonstrated in benchtop and porcine in vivo testing. The control method is robust even when pushed beyond the physical constraints of the system. Collectively, the material handling system provides a simple, repeatable way for an operator to interface with miniature in vivo robots, improving surgical system flexibility while minimizing impact on the duration of an abdominal surgical procedure.
Skip Nav Destination
University of Nebraska-Lincoln,
Lincoln, NE 68588-0526
e-mail: jeff.midday@yahoo.com
University of Nebraska-Lincoln,
Lincoln, NE 68588-0526;
Dept. of Surgery, Center for Advanced
Surgical Technology,
University of Nebraska Medical Center,
984075 Nebraska Medical Center,
Omaha, NE 68198-4075
e-mail: cnelson5@unl.edu
University of Nebraska-Lincoln,
Lincoln, NE 68588-0526
e-mail: alangoyzueta@gmail.com
Surgical Technology,
University of Nebraska Medical Center,
984075 Nebraska Medical Center,
e-mail: doleynik@unmc.edu
Article navigation
March 2013
Research-Article
Material Handling System for Robotic Natural Orifice Surgery
Jeff Midday,
University of Nebraska-Lincoln,
Lincoln, NE 68588-0526
e-mail: jeff.midday@yahoo.com
Jeff Midday
Dept. of Mechanical & Materials Engineering
,University of Nebraska-Lincoln,
W342 Nebraska Hall
,Lincoln, NE 68588-0526
e-mail: jeff.midday@yahoo.com
Search for other works by this author on:
Carl A. Nelson,
University of Nebraska-Lincoln,
Lincoln, NE 68588-0526;
Dept. of Surgery, Center for Advanced
Surgical Technology,
University of Nebraska Medical Center,
984075 Nebraska Medical Center,
Omaha, NE 68198-4075
e-mail: cnelson5@unl.edu
Carl A. Nelson
Dept. of Mechanical & Materials Engineering
,University of Nebraska-Lincoln,
W342 Nebraska Hall
Lincoln, NE 68588-0526;
Dept. of Surgery, Center for Advanced
Surgical Technology,
University of Nebraska Medical Center,
984075 Nebraska Medical Center,
Omaha, NE 68198-4075
e-mail: cnelson5@unl.edu
Search for other works by this author on:
Alan Goyzueta,
University of Nebraska-Lincoln,
Lincoln, NE 68588-0526
e-mail: alangoyzueta@gmail.com
Alan Goyzueta
Dept. of Mechanical & Materials Engineering
,University of Nebraska-Lincoln,
W342 Nebraska Hall
,Lincoln, NE 68588-0526
e-mail: alangoyzueta@gmail.com
Search for other works by this author on:
Dmitry Oleynikov
Surgical Technology,
University of Nebraska Medical Center,
984075 Nebraska Medical Center,
e-mail: doleynik@unmc.edu
Dmitry Oleynikov
Dept. of Surgery, Center for Advanced
Surgical Technology,
University of Nebraska Medical Center,
984075 Nebraska Medical Center,
Omaha, NE 68198-4075
e-mail: doleynik@unmc.edu
Search for other works by this author on:
Jeff Midday
Dept. of Mechanical & Materials Engineering
,University of Nebraska-Lincoln,
W342 Nebraska Hall
,Lincoln, NE 68588-0526
e-mail: jeff.midday@yahoo.com
Carl A. Nelson
Dept. of Mechanical & Materials Engineering
,University of Nebraska-Lincoln,
W342 Nebraska Hall
Lincoln, NE 68588-0526;
Dept. of Surgery, Center for Advanced
Surgical Technology,
University of Nebraska Medical Center,
984075 Nebraska Medical Center,
Omaha, NE 68198-4075
e-mail: cnelson5@unl.edu
Alan Goyzueta
Dept. of Mechanical & Materials Engineering
,University of Nebraska-Lincoln,
W342 Nebraska Hall
,Lincoln, NE 68588-0526
e-mail: alangoyzueta@gmail.com
Dmitry Oleynikov
Dept. of Surgery, Center for Advanced
Surgical Technology,
University of Nebraska Medical Center,
984075 Nebraska Medical Center,
Omaha, NE 68198-4075
e-mail: doleynik@unmc.edu
Manuscript received May 9, 2012; final manuscript received November 16, 2012; published online February 4, 2013. Editor: Gerald E. Miller.
J. Med. Devices. Mar 2013, 7(1): 011003 (7 pages)
Published Online: February 4, 2013
Article history
Received:
May 9, 2012
Revision Received:
November 16, 2012
Citation
Midday, J., Nelson, C. A., Goyzueta, A., and Oleynikov, D. (February 4, 2013). "Material Handling System for Robotic Natural Orifice Surgery." ASME. J. Med. Devices. March 2013; 7(1): 011003. https://doi.org/10.1115/1.4023265
Download citation file:
Get Email Alerts
Cited By
Smart Kidney Stone Basket: A Proof of Concept With Digital Feedback Force Monitoring
J. Med. Devices (June 2025)
A Portable Ultrasound-Guided Surgical System for Breast and Thyroid Surgery
J. Med. Devices (June 2025)
The History, Innovation, and Standards of Intravenous Access Ports and Devices
J. Med. Devices (June 2025)
Related Articles
Design Optimization of Single-Port Minimally Invasive Intervention Devices
J. Med. Devices (June,2009)
Material Handling System for Robotic Natural Orifice Surgery
J. Med. Devices (June,2011)
Utilization of Cable Guide Channels for Compact Articulation Within a Dexterous Three Degrees-of-Freedom Surgical Wrist Design
J. Med. Devices (March,2019)
Improvements to the Design of a Compact Robot for Minimally Invasive Surgery
J. Med. Devices (June,2011)
Related Proceedings Papers
Related Chapters
Time-Varying Coefficient Aided MM Scheme
Robot Manipulator Redundancy Resolution
A Mathematical Model and Heuristic Procedure for Cellular Layout
International Conference on Software Technology and Engineering, 3rd (ICSTE 2011)
Smart Control for Collective Agents by Adaptive Strategic Mechanism
Intelligent Engineering Systems through Artificial Neural Networks Volume 18