An orthopaedic hip implant is expected to support dynamic forces generated by human activities. To avoid progressive and localized damage caused by daily cyclic loading, the prosthesis is to be designed for fatigue under high cycle regime. Recently, a methodology has been developed to design a novel hip implant made of a cellular material with a periodic microarchitecture [1]. In contrast to current hip replacement implants typically made out of a fully solid material, which can be coated with a porous layer, this implant is completely porous. The microarchitecture of the material is a lattice displaying graded property distribution. The advantage of controlling the microarchitecture is twofold. First, the overall implant can be designed to be more compliant, which reduces stress shielding and bone resorption [2]. Second, the material porosity can be optimized to reduce bone-implant interface stresses, thereby lowering implant micromo-tion. Although encouraging, these results...
Skip Nav Destination
McGill University
Article navigation
June 2013
Technical Briefs
The Fatigue Design of a Bone Preserving Hip Implant With Functionally Graded Cellular Material
Damiano Pasini
McGill University
Damiano Pasini
Department of Mechanical Engineering
,McGill University
Search for other works by this author on:
Damiano Pasini
Department of Mechanical Engineering
,McGill University
Manuscript received March 15, 2013; final manuscript received April 24, 2013; published online June 5, 2013. Editor: Arthur G. Erdman.
J. Med. Devices. Jun 2013, 7(2): 020907 (2 pages)
Published Online: June 5, 2013
Article history
Received:
March 15, 2013
Revision Received:
April 24, 2013
Citation
Arabnejad Khanoki, S., and Pasini, D. (June 5, 2013). "The Fatigue Design of a Bone Preserving Hip Implant With Functionally Graded Cellular Material." ASME. J. Med. Devices. June 2013; 7(2): 020907. https://doi.org/10.1115/1.4024310
Download citation file:
Get Email Alerts
Cited By
Related Articles
Simulation of Physiological Loading in Total Hip Replacements
J Biomech Eng (August,2006)
Design and Validation of a Machine for Reproducible Precision Insertion of Femoral Hip Prostheses for Preclinical Testing
J Biomech Eng (April,2000)
Stress Analysis and Failure Prediction in the Proximal Femur Before and After Total Hip Replacement
J Biomech Eng (February,1986)
Effect of Geometrical Uncertainty on Cemented Hip Implant Structural Integrity
J Biomech Eng (May,2009)
Related Proceedings Papers
Related Chapters
Comparison of Loading Behavior of Femoral Stems of Ti-6Al-4V and Cobalt-Chromium Alloys: A Three-Dimensional Finite Element Analysis
Titanium Alloys in Surgical Implants
Long-Term Hydrostatic Strength and Design of Thermoplastic Piping Compounds
Plastic Pipe and Fittings: Past, Present, and Future
Study on Fatigue Design Loads for Ships Based on Crack Growth Analysis
Fatigue Testing and Analysis Under Variable Amplitude Loading Conditions