Both external and implantable devices are becoming more sophisticated and are requiring more on-chip memory to store data from biological sensors. To deal with this complexity, chip designs are moving toward smaller process geometries, which provide added functionality, reduced size, or both, often along with a reduction in dynamic power. However, leakage power begins to increase significantly at the 130nm node if steps are not taken to mitigate the increased transistor leakage. Lower operating voltages and careful transistor design can offset some of this increase. These very changes, however, make it difficult to design a dense, stable low-power SRAM. Nonvolatile memories like FRAM (F-RAM) avoid these difficulties and save power by simply turning off the memory when not in use. This is particularly valuable since many medical devices have very low duty cycle. FRAM provides the added benefit of providing SRAM-like active power, unlike competing nonvolatile technologies. To meet the challenging power requirements of medical devices, a new ultra-low-power 130nm process has been developed. The new process includes a very-high-density, SER-resistant, nonvolatile FRAM and an ultra-low-leakage transistor, coupled with a library that is optimized for low-power operation. This paper compares the power, area and performance of competing process technologies for a typical implantable medical design and highlights the advantages that FRAM provides in low static power through a transparent power-down capability and in low SRAM-like active power.
Skip Nav Destination
Article navigation
Design Of Medical Devices Conference Abstracts
TI Low-Leakage130nm Digital Process with Nonvolatile FRAM for Ultra-Low-Power Medical Electronics
A. Robert Landers,
A. Robert Landers
Texas Instruments
, Dallas, TX, USA
Search for other works by this author on:
B. Jerry Elkind,
B. Jerry Elkind
Texas Instruments
, Dallas, TX, USA
Search for other works by this author on:
C. Rajni Aggarwal
C. Rajni Aggarwal
Texas Instruments
, Dallas, TX, USA
Search for other works by this author on:
A. Robert Landers
Texas Instruments
, Dallas, TX, USA
B. Jerry Elkind
Texas Instruments
, Dallas, TX, USA
C. Rajni Aggarwal
Texas Instruments
, Dallas, TX, USAJ. Med. Devices. Jun 2008, 2(2): 027563 (1 pages)
Published Online: July 2, 2008
Article history
Published:
July 2, 2008
Citation
Landers, A. R., Elkind, B. J., and Aggarwal, C. R. (July 2, 2008). "TI Low-Leakage130nm Digital Process with Nonvolatile FRAM for Ultra-Low-Power Medical Electronics." ASME. J. Med. Devices. June 2008; 2(2): 027563. https://doi.org/10.1115/1.2932427
Download citation file:
442
Views
Get Email Alerts
Cited By
Context-Driven Design of a Laparoscopic Instrument Cleaner for Use in Rural Low-Resource Hospitals
J. Med. Devices (March 2025)
Controlled Ice Nucleation With a Sand-PDMS Film Device Enhances Cryopreservation of Mouse Preantral Ovarian Follicles
J. Med. Devices (December 2024)
Review of Blood and Fluid Warming Methods
J. Med. Devices (December 2024)
Related Articles
Distance Measuring Device Over Body Surface
J. Med. Devices (June,2009)
Self-Stimulatory Behavior Detection Using Wearable Sensors for Children With Autistic Spectrum Disorder
J. Med. Devices (June,2008)
A Low Power Wireless Data Acquisition Device to Monitor Gait Patterns for Children With Toe Walking During Daily Activities
J. Med. Devices (June,2011)
Diagnosis and Spectral Encoding in Integral Medicine Through Electronic Devices Designed and Developed by Path Integrals
J. Nanotechnol. Eng. Med (May,2011)
Related Proceedings Papers
Related Chapters
Introduction
Essentials of Electronic Packaging: A Multidisciplinary Approach
Vehicle Tracking Using an Efficient and Low Cost Embedded System with GPS and GSM
International Conference on Advanced Computer Theory and Engineering, 4th (ICACTE 2011)
Implementation of Embedded Model Development Environment Based on Eclipse RCP
International Conference on Information Technology and Management Engineering (ITME 2011)