Cardio-pulmonary resuscitation (CPR) plays an important role in the outcome of sudden cardiac arrest, where survival rates continue to be very low, about 5%. CPR has evolved significantly from the days when it was standard practice to flap the arms of victimes, or roll their bodies back and forth over a wooden barrel. Today, many people know the standard technique of giving chest compressions. Others may know about enhancement devices (e.g., ResQPOD) that use a basic mechanics concept of creating negative thoracic pressure during the decompression phase of CPR. This is done by adding inflow resistance to the patient's airway, such that a vacuum is created at each chest decompression. The vacuum pulls blood into the thorax, in effect “priming the pump” with more blood, which is then ejected in the next compression phase. We present an enhancement to the above proven concept of airway restriction during CPR by further adding total airway occlusion to the inflow and outflow of air at appropriate times, by use of a CPR enhancement device (CED). With a face mask and electronic airway valve, maximal vacuum and positive pressures are created in the thorax to enhance blood circulation during cardiac arrest. A CPR cycle is proposed with five phases including two for free air exchange, without the need to interrupt compressions, and adhering to AHA guidelines of 100 compressions per minute. To test the CED, a human cardiopulmonary model is described that allows blood pressure changes to be measured with the various forms of CPR, new and conventional. Preliminary data from testing both CED and standard CPR on the thorax model were found in terms of mean, systolic and diastolic pressure. T-tests evaluated statistical significance. During normal CPR, average systolic pressure was found to be mmHg. When the CED was applied, the average systolic pressure was found to be mmHg . Average diastolic pressure for normal CPR was found to be mmHg while that of the CED was observed to be mmHg . The MAP calculated from standard CPR resulted in an average of mmHg, while that using the CED was mmHg, . Based on this preliminary testing and data analysis, the CED shows a significant improvement in systolic and mean arterial pressure in comparison to standard CPR. This supports the CED five phase method that provides positive pressure and vacuum in the cardiopulmonary system during resuscitation. Future work will compare the CED to other CPR enhancement devices.
Skip Nav Destination
Article navigation
Design Of Medical Devices Conference Abstracts
Improved Cardiopulmonary Resucitation Device
B. Andreen,
B. Andreen
Biomedical Engineering 4001,
University of Minnesota
, Minneapolis, USA
Search for other works by this author on:
R. Croatt,
R. Croatt
Biomedical Engineering 4001,
University of Minnesota
, Minneapolis, USA
Search for other works by this author on:
T. Driscoll,
T. Driscoll
Biomedical Engineering 4001,
University of Minnesota
, Minneapolis, USA
Search for other works by this author on:
J. Savela,
J. Savela
Biomedical Engineering 4001,
University of Minnesota
, Minneapolis, USA
Search for other works by this author on:
A. Schwanbeck,
A. Schwanbeck
Biomedical Engineering 4001,
University of Minnesota
, Minneapolis, USA
Search for other works by this author on:
A. Zimmel,
A. Zimmel
Biomedical Engineering 4001,
University of Minnesota
, Minneapolis, USA
Search for other works by this author on:
A. Belalcazar
A. Belalcazar
Biomedical Engineering 4001,
University of Minnesota
, Minneapolis, USA
Search for other works by this author on:
B. Andreen
Biomedical Engineering 4001,
University of Minnesota
, Minneapolis, USA
R. Croatt
Biomedical Engineering 4001,
University of Minnesota
, Minneapolis, USA
T. Driscoll
Biomedical Engineering 4001,
University of Minnesota
, Minneapolis, USA
J. Savela
Biomedical Engineering 4001,
University of Minnesota
, Minneapolis, USA
A. Schwanbeck
Biomedical Engineering 4001,
University of Minnesota
, Minneapolis, USA
A. Zimmel
Biomedical Engineering 4001,
University of Minnesota
, Minneapolis, USA
A. Belalcazar
Biomedical Engineering 4001,
University of Minnesota
, Minneapolis, USAJ. Med. Devices. Jun 2009, 3(2): 027502 (1 pages)
Published Online: June 29, 2009
Article history
Published:
June 29, 2009
Citation
Andreen, B., Croatt, R., Driscoll, T., Savela, J., Schwanbeck, A., Zimmel, A., and Belalcazar, A. (June 29, 2009). "Improved Cardiopulmonary Resucitation Device." ASME. J. Med. Devices. June 2009; 3(2): 027502. https://doi.org/10.1115/1.3134784
Download citation file:
553
Views
Get Email Alerts
Cited By
Context-Driven Design of a Laparoscopic Instrument Cleaner for Use in Rural Low-Resource Hospitals
J. Med. Devices (March 2025)
Controlled Ice Nucleation With a Sand-PDMS Film Device Enhances Cryopreservation of Mouse Preantral Ovarian Follicles
J. Med. Devices (December 2024)
Review of Blood and Fluid Warming Methods
J. Med. Devices (December 2024)
Related Articles
Evolution of a Non-Invasive Method for Providing Assistance to the Heart
J. Med. Devices (June,2009)
Computational Modeling of Blood Hydrodynamics and Blockage Formation Phenomena in the Human Cardiovascular System
J. Med. Devices (June,2010)
Development of A Medical Device for Quantitative Physical Therapies
J. Med. Devices (June,2008)
A 2D Model With Fluid-Structure Interactions for Coarctated Arteries
J. Med. Devices (June,2011)
Related Proceedings Papers
Related Chapters
Occlusion Identification and Relief within Branched Structures
Biomedical Applications of Vibration and Acoustics in Therapy, Bioeffect and Modeling
Section III: Subsections NC and ND — Class 2 and 3 Components
Companion Guide to the ASME Boiler and Pressure Vessel Code, Volume 1, Third Edition
Specific Device Examples
Magnetic Bearings for Mechanical Cardiac Assist Devices