Colon cancer is the second leading cause of cancer-related death in the United States. Colonoscopy is the best technology available to detect and treat abnormalities within the colon. It is a procedure that enables a gastroenterologist to evaluate the appearance of the inside of the colon by inserting a flexible tube with about 3/8 in diameter into the anus, and then advancing it slowly, under visual control, into the rectum and through the colon. This procedure is often onerous due to that the driving of the bending section (tip) of the scope and perforation may occur with the rate of 1 out of 1700 procedures. The tip driving system consists of two angulation knobs, two chain-sprocket mechanisms, a series of ring-pivot mechanism, and two pair of wires. Rotating each knob extends and retracts a pair of wires which changes the orientation of the bending section. The up/down angulation knob generates an elevation motion and the left/right angulation knob generates an azimuth motion. Based on the traditional colonoscopy, this work developed an intelligent technology to extend and enhance the diagnostic and surgical capability of the instrument. This intelligent colonoscope includes an image-based control of the tip to release a doctor from onerous work, advanced imaging systems for diagnostics, and advanced human-machine interfaces to facilitate the doctor's operation in an effective manner. In the realization of the bending section driving automation, the driving mechanism design is one of the key issues. In our design of the bending section motion control mechanism, the handle of the colonoscope and the motors are fixed on a holder. The holder can travel along a track. The track can be fixed on any flat surface such as a desk in order to enlarge the motion range of the colonoscope body. Belt mechanism is used to translate the motion from motors to the knobs. The belt pulley is fixed on the driving knob through four equally distributed screws. In order to keep the belt tied all the time, a rocker mechanism with a spring is used between the motor and the knob. Two motors are used to drive the two angulation knobs. Two limit switches are used to identify the homing position of the two motors. The driving torque is limited through the constraint of the current supplied to the motor by an amplifier to avoid the damage to the mechanical system. Together with the motion control system, the mechanism has been lab-tested using an artificial colon. It is observed that the mechanism performs well to accomplish the automation of the knob driving tasks. The system has also been tested using a pig in the animal lab of a hospital satisfactory results have been obtained.
Skip Nav Destination
Article navigation
Design Of Medical Devices Conference Abstracts
Design of a Bending Section Auto-Driven Mechanism for Colonoscope
D. Zhou,
D. Zhou
Department of Mechanical and Industrial Engineering,
University of Minnesota
, Duluth, MN 55812
Search for other works by this author on:
G. McMurray
G. McMurray
Food Processing Technology Division,
Georgia Tech Research Institute
, Atlanta, GA, 30332
Search for other works by this author on:
D. Zhou
Department of Mechanical and Industrial Engineering,
University of Minnesota
, Duluth, MN 55812
G. McMurray
Food Processing Technology Division,
Georgia Tech Research Institute
, Atlanta, GA, 30332J. Med. Devices. Jun 2009, 3(2): 027508 (1 pages)
Published Online: June 30, 2009
Article history
Published:
June 30, 2009
Citation
Zhou, D., and McMurray, G. (June 30, 2009). "Design of a Bending Section Auto-Driven Mechanism for Colonoscope." ASME. J. Med. Devices. June 2009; 3(2): 027508. https://doi.org/10.1115/1.3135121
Download citation file:
1,452
Views
Get Email Alerts
Cited By
Context-Driven Design of a Laparoscopic Instrument Cleaner for Use in Rural Low-Resource Hospitals
J. Med. Devices (March 2025)
Controlled Ice Nucleation With a Sand-PDMS Film Device Enhances Cryopreservation of Mouse Preantral Ovarian Follicles
J. Med. Devices (December 2024)
Review of Blood and Fluid Warming Methods
J. Med. Devices (December 2024)
Related Articles
Kinematic and Workspace Comparison of Four and Five Degree of Freedom Miniature In Vivo Surgical Robot
J. Med. Devices (June,2011)
Localization of the Distal Tip in the Colonoscopy Training Model Using Light Sensors
J. Med. Devices (June,2011)
An Articulating Tool for Endoscopic Screw Delivery
J. Med. Devices (June,2010)
Automated 3D Mosaicing and Scan Trajectories for Surveillance of Bladder Cancer
J. Med. Devices (June,2011)
Related Proceedings Papers
Related Chapters
Computer Aided Machine Design
Computer Aided Design and Manufacturing
Cyber-Physical Systems, Blended Tool Environments, and Playful Creativity
Advances in Computers and Information in Engineering Research, Volume 2
Constructing Dynamic Event Trees from Markov Models (PSAM-0369)
Proceedings of the Eighth International Conference on Probabilistic Safety Assessment & Management (PSAM)