A monopolar electrosurgical device is the most commonly used energy-based surgical instrument. Monopolar devices are primarily applied to incise, ablate, dissect, and coagulate tissue by transferring electrical energy to the tissue in the form of heat generation through resistive heating. The substantial amount of heat created by the monopolar device has been shown to spread throughout the tissue, creating unintended tissue damage, which can lead to nerve thermal damage and loss of normal bodily functions. Due to this fact, energy-based devices have had a limited use in surgical procedures performed near neurovascular bundles. The extent to which the generated heat raises the temperature of the surrounding tissue is referred to as the device’s thermal spread. In this study, ex vivo and in vivo experiments have shown that a novel thermal management system (TMS) can reduce the amount of thermal spread created by a typical monopolar device, thus eliminating the thermal collateral tissue damage typically caused during a monopolar procedure. The incorporation of a TMS consisting of adjacent cooling channels reduces the thermal spread of the device, as illustrated in a reduction as high as 50% in the maximum temperature recorded during an in vivo experimental procedure. The design of the TMS was aided by finite element modeling (FEM). The phenomenon of monopolar resistive heating was modeled to analyze the temperature distributions in biological tissue subjected to heat generation by a commonly used monopolar electrosurgical device. The mathematical model was verified by comparing the model’s predicted temperature distribution with experimental results. Ex vivo experiments were performed with liver tissue heated by a monopolar pencil electrode. The experimental data for 1 mm distance from the electrode are seen to fit within 1% of the predicted temperature values by the FEM simulation.
Skip Nav Destination
Article navigation
Design Of Medical Devices Conference Abstracts
Monopolar Electrosurgical Thermal Management System to Reduce Lateral Thermal Damage During Surgery
James D. Geiger,
James D. Geiger
Medical School,
University of Michigan
Search for other works by this author on:
Albert J. Shih
Albert J. Shih
University of Michigan
Search for other works by this author on:
Robert Dodde
University of Michigan
Jacob S. Gee
University of Michigan
James D. Geiger
Medical School,
University of Michigan
Albert J. Shih
University of Michigan
J. Med. Devices. Jun 2010, 4(2): 027505 (1 pages)
Published Online: August 9, 2010
Article history
Online:
August 9, 2010
Published:
August 9, 2010
Citation
Dodde, R., Gee, J. S., Geiger, J. D., and Shih, A. J. (August 9, 2010). "Monopolar Electrosurgical Thermal Management System to Reduce Lateral Thermal Damage During Surgery." ASME. J. Med. Devices. June 2010; 4(2): 027505. https://doi.org/10.1115/1.3439653
Download citation file:
Get Email Alerts
Cited By
Context-Driven Design of a Laparoscopic Instrument Cleaner for Use in Rural Low-Resource Hospitals
J. Med. Devices (March 2025)
Related Articles
Pre-Clinical Evaluation of Direct Current Ablation for the Treatment of Benign Prostatic Hyperplasia
J. Med. Devices (June,2009)
Minimizing Invasiveness of Liver Resection Using an Integrated Tissue Ablation and Division Device With Blood Flow Sensing
J. Med. Devices (December,2013)
Electrical Impedance Tomography of Cell Viability in Tissue With Application to Cryosurgery
J Biomech Eng (April,2004)
Thermal-Electric Finite Element Analysis and Experimental Validation of Bipolar Electrosurgical Cautery
J. Manuf. Sci. Eng (April,2008)
Related Proceedings Papers
Related Chapters
Role of Artificial Intelligence in Hepatitis B Diagnosis
International Conference on Mechanical and Electrical Technology, 3rd, (ICMET-China 2011), Volumes 1–3
The Complementary DNA Segment Cloning and Bioinformatics Analysis of INTS2 Gene in Goose
International Conference on Computer Technology and Development, 3rd (ICCTD 2011)
STRUCTURAL RELIABILITY ASSESSMENT OF PIPELINE GIRTH WELDS USING GAUSSIAN PROCESS REGRESSION
Pipeline Integrity Management Under Geohazard Conditions (PIMG)