Video capsule endoscopy (VCE) is a method used to wirelessly scan the gastrointestinal (GI) tract lumen. Despite the effectiveness of VCE in GI endoscopic procedures, VCE is limited because it lacks the capability to exactly locate itself as well as accurately detect bleeding or clotting within the GI tract. The unreliability of localization combined with inaccurate blood detection in VCE ultimately leads to wired endoscopy for additional diagnosis. In this paper, a method to address localization of the VCE device, also known as a pill camera or capsule, in conjunction with an accurate detection of active bleeding and clotting inside the small intestine, is introduced. The Texas Instruments, ZigBee® kit, which uses a 3D trilateration method will be used for accurate location detection and image transmission throughout the VCE procedure. The system will be interfaced with software providing end users with the path and total distance traveled by the pill capsule within the small intestine. The blood detection system is enhanced by using a minilow energy wireless Raman spectrometry to scan for active bleeding or clots along the small intestinal wall. The employed spectrometry method scans for wavelengths based on blood’s optical characteristics and records any image fitting the exact spectrum. Blood detection and localization data are coupled together and then transferred to an external receiver. These two improvements together will enhance capsule endoscopy procedures and fill the gap created by the existing capsule endoscopy technologies, therefore, meeting the needs of physicians and patients.
Skip Nav Destination
Article navigation
Design Of Medical Devices Conference Abstracts
Enhancing Video Capsule Endoscopy: Location and Bleeding Detection
Yurika Inoue,
Yurika Inoue
University of Michigan
, Ann Arbor
Search for other works by this author on:
Amir Sabet Sarvestani,
Amir Sabet Sarvestani
University of Michigan
, Ann Arbor
Search for other works by this author on:
Jonathan Yap,
Jonathan Yap
University of Michigan
, Ann Arbor
Search for other works by this author on:
Douglas L. Yeung
Douglas L. Yeung
University of Michigan
, Ann Arbor
Search for other works by this author on:
Yurika Inoue
University of Michigan
, Ann Arbor
Amir Sabet Sarvestani
University of Michigan
, Ann Arbor
Jonathan Yap
University of Michigan
, Ann Arbor
Douglas L. Yeung
University of Michigan
, Ann ArborJ. Med. Devices. Jun 2010, 4(2): 027525 (1 pages)
Published Online: August 10, 2010
Article history
Published:
August 10, 2010
Citation
Inoue, Y., Sarvestani, A. S., Yap, J., and Yeung, D. L. (August 10, 2010). "Enhancing Video Capsule Endoscopy: Location and Bleeding Detection." ASME. J. Med. Devices. June 2010; 4(2): 027525. https://doi.org/10.1115/1.3443260
Download citation file:
Get Email Alerts
Cited By
Context-Driven Design of a Laparoscopic Instrument Cleaner for Use in Rural Low-Resource Hospitals
J. Med. Devices (March 2025)
Controlled Ice Nucleation With a Sand-PDMS Film Device Enhances Cryopreservation of Mouse Preantral Ovarian Follicles
J. Med. Devices (December 2024)
Review of Blood and Fluid Warming Methods
J. Med. Devices (December 2024)
Related Articles
Comparison of Video Laryngoscopy Technologies
J. Med. Devices (June,2009)
Design of an Endoscopic Biopsy Needle
J. Med. Devices (June,2010)
Integrating Physicians, Researchers and Engineers— 60 Years of Medical Device Innovation at Mayo Clinic
J. Med. Devices (June,2008)
Design of a Compliant Endoscopic Suturing Instrument
J. Med. Devices (June,2008)
Related Proceedings Papers
Related Chapters
Real-Time People Counting System Using an Uncalibrated Video Camera
International Conference on Software Technology and Engineering (ICSTE 2012)
Integrated Video Content Analysis Using Multiple Uncalibrated Video Camera for Loitering Detection
International Conference on Software Technology and Engineering (ICSTE 2012)
Research on the Relation of the Dispels Voltage and Compensating Voltage in Flat FAIMS
International Conference on Information Technology and Computer Science, 3rd (ITCS 2011)