Skip Nav Destination
Issues
December 2014
ISSN 1932-6181
EISSN 1932-619X
In this Issue
Research Papers
A Novel Structure of a Less Invasive Forceps to Realize Linear Clamping for Endoscopic Surgery
J. Med. Devices. December 2014, 8(4): 041001.
doi: https://doi.org/10.1115/1.4026829
Topics:
Biological tissues
,
Endoscopic devices
,
Pressure
,
Surgery
,
Wire
,
Tension
Computational Assessment of Stent Durability Using Fatigue to Fracture Approach
J. Med. Devices. December 2014, 8(4): 041002.
doi: https://doi.org/10.1115/1.4027687
Topics:
Fatigue
,
Fracture (Materials)
,
Stents
,
Stress
,
Durability
Determination of Optimal Counter-Mass Location in Active Prostheses for Transfemoral Amputees to Replicate Sound Limb Swing
J. Med. Devices. December 2014, 8(4): 041003.
doi: https://doi.org/10.1115/1.4027231
Topics:
Artificial limbs
,
Computers
,
Kinematics
,
Knee
,
Prostheses
A Dual-Arm 7-Degrees-of-Freedom Haptics-Enabled Teleoperation Test Bed for Minimally Invasive Surgery
J. Med. Devices. December 2014, 8(4): 041004.
doi: https://doi.org/10.1115/1.4026984
Topics:
Haptics
,
Kinematics
,
Surgery
,
Design
Fractional Skin Harvesting: Device Operational Principles and Deployment Evaluation
Walfre Franco, Joel N. Jimenez-Lozano, Joshua Tam, Martin Purschke, Ying Wang, Fernanda H. Sakamoto, William A. Farinelli, Apostolos G. Doukas, R. Rox Anderson
J. Med. Devices. December 2014, 8(4): 041005.
doi: https://doi.org/10.1115/1.4027427
Topics:
Needles
,
Skin
,
Biological tissues
Bone Anchors—A Preliminary Finite Element Study of Some Factors Affecting Pullout
J. Med. Devices. December 2014, 8(4): 041006.
doi: https://doi.org/10.1115/1.4026901
Amputee Subject Testing Protocol, Results, and Analysis of a Powered Transtibial Prosthetic Device
J. Med. Devices. December 2014, 8(4): 041007.
doi: https://doi.org/10.1115/1.4027497
Topics:
Prostheses
,
Testing
Development and Validation of Endovascular Chemotherapy Filter Device for Removing High-Dose Doxorubicin: Preclinical Study
Anand S. Patel, Maythem Saeed, Erin J. Yee, Jeffrey Yang, Gregory J. Lam, Aaron D. Losey, Prasheel V. Lillaney, Bradford Thorne, Albert K. Chin, Sheena Malik, Mark W. Wilson, Xi C. Chen, Nitash P. Balsara, Steven W. Hetts
J. Med. Devices. December 2014, 8(4): 041008.
doi: https://doi.org/10.1115/1.4027444
Topics:
Blood
,
Catheters
,
Filters
,
Flow (Dynamics)
,
Information Analysis Centers
,
Liver
,
Resins
,
Drugs
,
Filtration
,
Cancer
Bioinspired Crown-Cutter—The Impact of Tooth Quantity and Bevel Type on Tissue Deformation, Penetration Forces, and Tooth Collapsibility
J. Med. Devices. December 2014, 8(4): 041009.
doi: https://doi.org/10.1115/1.4027054
Topics:
Biological tissues
,
Deformation
,
Design
,
Biomimetics
,
Surgery
,
Gelatin
,
Seas
Scala-Tympani Phantom With Cochleostomy and Round-Window Openings for Cochlear-Implant Insertion Experiments
J. Med. Devices. December 2014, 8(4): 041010.
doi: https://doi.org/10.1115/1.4027617
Topics:
Electrodes
,
Phantoms
,
Cochlear implants
Experimental Characterization and Control of Miniaturized Pneumatic Artificial Muscle
J. Med. Devices. December 2014, 8(4): 041011.
doi: https://doi.org/10.1115/1.4028420
Topics:
Actuators
,
Braid (Textile)
,
Control equipment
,
Kinematics
,
Muscle
,
Pressure
,
Surgical tools
,
Surgery
,
Design
,
Experimental characterization
Finite-Element Study of the Performance Characteristics of an Intradural Spinal Cord Stimulator
Nicole M. Grosland, George T. Gillies, Robert Shurig, Kirsten Stoner, Stephanus Viljoen, Brian D. Dalm, Hiroyuki Oya, Douglas C. Fredericks, Katherine Gibson-Corley, Chandan Reddy, Saul Wilson, Matthew A. Howard, III
J. Med. Devices. December 2014, 8(4): 041012.
doi: https://doi.org/10.1115/1.4028421
Technical Brief
Design and Research of a Robotic Aided System for Retinal Vascular Bypass Surgery
J. Med. Devices. December 2014, 8(4): 044501.
doi: https://doi.org/10.1115/1.4027230
Topics:
Design
,
Robotics
,
Robots
,
Surgery
,
Instrumentation
,
End effectors
,
Path planning
Design and Preliminary Testing of a Pneumatic Muscle-Actuated Transfemoral Prosthesis
J. Med. Devices. December 2014, 8(4): 044502.
doi: https://doi.org/10.1115/1.4026830
Developing a Mobile Lower Limb Robotic Exoskeleton for Gait Rehabilitation
J. Med. Devices. December 2014, 8(4): 044503.
doi: https://doi.org/10.1115/1.4026900
Customizable Soft Pneumatic Chamber–Gripper Devices for Delicate Surgical Manipulation
J. Med. Devices. December 2014, 8(4): 044504.
doi: https://doi.org/10.1115/1.4027688
Stereotactic Radiosurgery Head Phantom Bite Tray Fit Reproducibility
J. Med. Devices. December 2014, 8(4): 044505.
doi: https://doi.org/10.1115/1.4027677
Topics:
Phantoms
,
Radiation therapy
Flexible Mechanical Joint as Human Exoskeleton Using Low-Melting-Point Alloy
J. Med. Devices. December 2014, 8(4): 044506.
doi: https://doi.org/10.1115/1.4028307
Topics:
Alloys
,
Exoskeleton devices
,
Melting
,
Paraffin wax
Mechatronic System for ABO Human Blood Typing
J. Med. Devices. December 2014, 8(4): 044507.
doi: https://doi.org/10.1115/1.4028201
Topics:
Blood
,
Engineering prototypes
A New Method to Intra-Operatively Measure Local Bone Strength in Osteoporotic Bone Using a Modified Surgical Tool
J. Med. Devices. December 2014, 8(4): 044508.
doi: https://doi.org/10.1115/1.4028475
Topics:
Bone
,
Osteoporosis
,
Screws
,
Surgical tools
Design Innovation Paper
Noninvasive Urinary Incontinence Control Device
J. Med. Devices. December 2014, 8(4): 045001.
doi: https://doi.org/10.1115/1.4027870
Low Cost Magnetic Resonance Imaging-Compatible Stepper Exercise Device for Use in Cardiac Stress Tests
Omid Forouzan, Evan Flink, Jared Warczytowa, Nick Thate, Andrew Hanske, Tongkeun Lee, Alejandro Roldan-Alzate, Chris François, Oliver Wieben, Naomi C. Chesler
J. Med. Devices. December 2014, 8(4): 045002.
doi: https://doi.org/10.1115/1.4027343
Topics:
Flow (Dynamics)
,
Imaging
,
Levers
,
Magnetic resonance
,
Magnetic resonance imaging
,
Stress
,
Wafer steppers
,
Testing
,
Weight (Mass)
Email alerts
RSS Feeds
Context-Driven Design of a Laparoscopic Instrument Cleaner for Use in Rural Low-Resource Hospitals
J. Med. Devices (March 2025)
Controlled Ice Nucleation With a Sand-PDMS Film Device Enhances Cryopreservation of Mouse Preantral Ovarian Follicles
J. Med. Devices (December 2024)
Review of Blood and Fluid Warming Methods
J. Med. Devices (December 2024)