Many studies assessing the damage from 1971 San Fernando and 1994 North Ridge earthquakes reported that the failure of nonstructural components like piping systems was one of the significant reasons for shutdown of hospitals immediately after the earthquakes. This paper is focused on evaluating seismic fragility of a large-scale piping system in representative high-rise, midrise, and low-rise buildings using nonlinear time history analyses. The emphasis is on evaluating piping's interaction with building and its effect on piping fragility. The building models include the effects of nonlinearity in the performance of beams and columns. In a 20-story building that is detuned with the piping system, critical locations are on the top two floors for the linear frame building model. For the nonlinear building model, critical locations are on the bottom two floors. In an eight-story building that is nearly tuned with the piping system, the critical locations for both the linear frame and nonlinear models are the third and fourth floors. It is observed that building nonlinearity can reduce fragility due to reduction in the tuning between building and piping systems. In a two-story building, the nonlinear building frequencies are closer to the critical piping system frequencies than the linear building frequency; the nonlinear building is more fragile than the linear building for this case. However, it is observed that the linear building models give excessively conservative estimates of fragility than the nonlinear building models.

References

1.
FEMA 577
,
2007
, “Design Guide for Improving Hospital Safety in Earthquakes, Floods, and High Winds: Providing Protection to People and Buildings (2007),” Federal, Emergency Management Agency, Washington, DC,
Report
.https://www.fema.gov/media-library/assets/documents/10672
2.
Ayres
,
J. M.
, and
Phillips
,
R. J.
,
1998
, “
Water Damage in Hospitals Resulting From the Northridge Earthquake
,”
ASHRAE Trans.
,
104
(
Pt. 1B
), pp. 1286–1296.
3.
Bachman
,
R.
,
Bonowitz
,
D.
,
Caldwell
.
P. J.
,
Filiatrault
,
A.
,
Kennedy
,
R. P.
,
McGavin
,
G.
, and
Miranda
,
E.
,
2004
, “Engineering Demand Parameters for Nonstructural Components,” Applied Technology Council, Redwood City, CA, Report No.
ATC-58
.https://www.atcouncil.org/pdfs/atc582t23.pdf
4.
Ju
,
B. S.
,
Gupta
,
A.
, and
Ryu
,
Y. H.
,
2017
, “
Piping Fragility Evaluation: Interaction With High-Rise Building Performance
,”
ASME J. Pressure Vessel Technol.
,
139
(
3
), p.
031801
.
5.
Ryu
,
Y.
,
Gupta
,
A.
,
Jung
,
W.
, and
Ju
,
B.
,
2016
, “
A Reconciliation of Experimental and Analytical Results for Piping Systems
,”
Int. J. Steel Struct.
,
16
(
4
), pp.
1043
1055
.
6.
Wood
,
R. L.
,
Hutchinson
,
T. C.
,
Lee
,
C.
, and
Grigoriu
,
M. D.
,
2012
, “Fragility Function Development for Nonstructural Component Systems,” NEESR-GC: Simulation of the Seismic Performance of Nonstructural Systems, Structural Systems Research Project Report Series, University of California, San Diego, CA, Techinical Report No. 2009 SSRP 09/1.
7.
International Building Code (IBC)
,
2006
, “International Building Code 2006,” International Code Council, Falls Church, VA.
8.
ACI
,
2014
, “Building Code Requirements for Structural Concrete,” American Concrete Institute, Farmington Hills, MI, Report No. ACI 318-14.
9.
Mazzoni
,
S.
,
Mckenna
,
F.
,
Scott
,
M. H.
, and
Fenves
,
G. L.
,
2006
, “OpenSees Command Language Manual, Open System for Earthquake Engineering Simulation (OpenSees),” University of California, Berkeley, CA, accessed Jan. 24, 2018, http://opensees.berkeley.edu/
10.
Scott
,
M. H.
, and
Fenves
,
G. L.
,
2006
, “
Plastic Hinge Integration Methods for Force-Based Beam-Column Elements
,”
ASCE J. Struct. Eng.
,
132
(
2
), pp.
244
252
.
11.
Paulay
,
T.
, and
Priestley
,
M. J. N.
,
1992
,
Seismic Design of Reinforced Concrete and Masonry Buildings
,
Wiley
, Hoboken, NJ.
12.
Ryu
,
Y.
,
2013
, “Fragility of Piping Systems and Reliability of Piping Components,”
Ph.D. dissertation
, North Carolina State University, Raleigh, NC.https://repository.lib.ncsu.edu/handle/1840.16/8532
13.
Ayers
,
J. M.
,
1996
,
Northridge Earthquake Hospital Water Damage Study
,
Ayers & Ezers Associates
,
Los Angeles, CA
.
14.
FEMA P695
,
2009
, “Quantification of Building Seismic Performance Factors,” Federal Emergency Management Agency, Washington, DC,
Report
https://www.fema.gov/media-library-data/20130726-1716-25045-9655/fema_p695.pdf.
15.
Ju
,
B.-S.
,
Tadinada
,
S. K.
, and
Gupta
,
A.
,
2011
, “Fragility Analysis of Threaded T-Joint Connections in Hospital Piping Systems,”
ASME
Paper No. PVP2011-57958.
16.
ASME,
2007
, “Rule for Construction of Nuclear Facility Components,” American Society of Mechanical Engineers, New York, ASME Boiler and Pressure Vessel Code, Section III.
17.
ASCE/SEI,
2005
, “Seismic Design Criteria for Structures, Systems, and Components in Nuclear Facilities,” American Society of Civil Engineers and Structural Engineering Institute, Reston, VA, Standard No.
ASCE/SEI 43-05
.https://ascelibrary.org/doi/book/10.1061/9780784407622
18.
USNRC
,
2007
, “A Performance-Based Approach to Define the Site-Specific Earthquake Ground Motions,” Regulatory Guide 1.208, U.S. Nuclear Regulatory Commission, Washington, DC.
19.
Tian
,
Y.
,
Filiatrault
,
A.
, and
Mosqueda
,
G.
,
2015
, “Seismic Response of Pressurized Fire Sprinkler Piping Systems II: Numerical Study,”
J. Earthq. Eng.
,
19
(
4
), pp.
674
699
.
20.
EPRI
,
1994
, “Methodology for Developing Seismic Fragilities,” Electric Power Research Institute, Palo Alto, CA, Report No.
EPRI TR-103959
.https://www.epri.com/#/pages/product/TR-103959/
21.
Gupta
,
A.
, and
Bose
,
M. K.
,
2017
, “
Significance of Non-Classical Damping in Seismic Qualification of Equipment and Piping
,”
Nucl. Eng. Des.
,
317
, pp.
90
99
.
22.
Gupta
,
A.
,
1999
, “
Significance of Nonclassical Damping in Coupled System Analysis
,”
15th Structural Mechanics in Reactor Technology Conference
,
Seoul, Korea
,
Aug. 15–20
.
23.
Ryu
,
Y. H.
,
Jung
,
W. Y.
, and
Ju
,
B. S.
,
2016
, “
Vibration Effects of Nonclassically Damped Building-Piping Systems Subjected to Extreme Loads
,”
Shock Vib.
,
2016
, p.
6189326
.
You do not currently have access to this content.