A detailed model for use with TRNSYS, capable of modelling a wide range of boiling collector types, was used to analyze boiling flat-plate collector systems. This model can account for a subcooled liquid entering the collector, heat losses in the vapor and the liquid return line, pressure drops due to friction in the collector and piping, and pressure drops due to the hydrostatic head of the fluid. The model has been used to determine the yearly performance of boiling flat-plate solar collector systems. A simplified approach was also developed which can be used with the f-Chart method to predict yearly performance of boiling flat-plate collector systems.
Issue Section:
Research Papers
Topics:
Boiling,
Flat plates,
Pressure drop,
Fluids,
Friction,
Heat losses,
Hydrostatics,
Modeling,
Pipes,
Solar collectors,
Subcooling,
Vapors
This content is only available via PDF.
Copyright © 1986
by ASME
You do not currently have access to this content.