Abstract

There is basically no research on the impact of rural residents' behavior on heating when using gas-fired heating and hot water combi-boilers as a heat source. Two residential buildings in rural areas of Handan were selected for the study, indoor and outdoor temperatures and gas consumption were tested, and a survey of residents' behavior was conducted. The results show that the ratio of actual heat inputs to rated heat input in two buildings is 47–76% and 25–91%, indicating that the reason for the indoor temperature being lower than design temperature is not the insufficient heating capacity of the heating system, but rather the result of residents actively adjusting the combi-boilers. Resident behavior adjustment has a significant impact on the temperature difference between indoor and outdoor and gas consumption for heating. Compared to the automatic adjustment behavior mode, the maximum deviation of the temperature difference between indoor and outdoor under artificial adjustment behavior during period 1 is 59%, with an average deviation of 44%. However, the average gas consumption is reduced by 9.2%. The study reflects that rural residents actively adjust the gas-fired combi-boilers to significantly reduce the gas cost of building heating while meeting their own thermal comfort requirements.

References

1.
Fan
,
M.
,
He
,
G.
, and
Zhou
,
M.
,
2020
, “
The Winter Choke: Coal-Fired Heating, Air Pollution, and Mortality in China
,”
J. Health Econ.
,
71
, p.
102316
.
2.
Duan
,
X.
,
Jiang
,
Y.
,
Wang
,
B.
,
Zhao
,
X.
,
Shen
,
G.
,
Cao
,
S.
,
Huang
,
N.
,
Qian
,
Y.
,
Chen
,
Y.
, and
Wang
,
L.
,
2014
, “
Household Fuel Use for Cooking and Heating in China: Results From the First Chinese Environmental Exposure-Related Human Activity Patterns Survey (CEERHAPS)
,”
Appl. Energy
,
136
, pp.
692
703
.
3.
Wang
,
J.
,
Zhou
,
Z.
,
Zhao
,
J.
,
Zheng
,
J.
, and
Guan
,
Z.
,
2019
, “
Towards a Cleaner Domestic Heating Sector in China: Current Situations, Implementation Strategies, and Supporting Measures
,”
Appl. Therm. Eng.
,
152
, pp.
515
531
.
4.
Feng
,
Z.
,
Wang
,
W.
,
He
,
X.
,
Li
,
G.
,
Zhang
,
L.
, and
Xiang
,
W.
,
2023
, “
Energy Saving Optimization of Chilled Water System Based on Improved Fruit fly Optimization Algorithm
,”
ASME J. Therm. Sci. Eng. Appl.
,
15
(
8
), p.
081010
.
5.
National Development and Reform Commission (NDRC)
,
2017
, “The Plan of Clean Heating in Northern Areas in Winter (2017–2021).” https://www.gov.cn/xinwen/2017-12/20/5248855/files/7ed7d7cda8984ae39a4e9620a4660c7f.pdf
6.
Zhou
,
S.
,
Sun
,
H.
,
Wang
,
C.
, and
Liang
,
Y.
,
2020
, “
Policy-Driven Clean Heating Modes in the Rural Areas of the Northern China
,”
Nat. Gas Ind.
,
40
(
3
), pp.
146
156
. CNKI:SUN:TRQG.0.2020-03-029
7.
Ma
,
R.
,
Mao
,
C.
,
Ding
,
X.
,
Deng
,
M.
,
Baumgartner
,
J.
,
Wang
,
X.
,
Wang
,
X.
, et al
,
2020
, “
Diverse Heating Demands of a Household Based on Occupant Control Behavior of Individual Heating Equipment
,”
Energy Build.
,
207
, p.
109612
.
8.
Yan
,
Y.
,
Jiao
,
W.
,
Wang
,
K.
,
Huang
,
Y.
,
Chen
,
J.
, and
Han
,
Q.
,
2020
, “
Coal-to-Gas Heating Compensation Standard and Willingness to Make Clean Energy Choices in Typical Rural Areas of Northern China
,”
Energy Policy
,
145
, p.
111698
.
9.
Zhang
,
Z.
,
Zhou
,
Y.
,
Zhao
,
N.
,
Li
,
H.
,
Tohniyaz
,
B.
,
Mperejekumana
,
P.
,
Hong
,
Q.
, et al
,
2021
, “
Clean Heating During Winter Season in Northern China: A Review
,”
Renew. Sustain. Energy Rev.
,
149
, p.
111339
.
10.
Zheng
,
W.
,
Zhang
,
Y.
,
Xia
,
J.
, and
Jiang
,
Y.
,
2020
, “
Cleaner Heating in Northern China: Potentials and Regional Balances
,”
Resour. Conserv. Recycl.
,
160
, p.
10487
.
11.
Liu
,
W.
,
Zhou
,
W.
,
Yang
,
L.
,
,
X.
, and
Liu
,
G.
,
2020
, “
Investigation on the Performance Evaluation of Gas-Fired Combi-Boilers With Factor Analysis and Cluster Analysis
,”
SN Appl. Sci.
,
2
(
6
), p.
1132
.
12.
Zhou
,
W.
,
Liu
,
W.
,
Long
,
F.
, and
Zhang
,
J.
, “
Experimental Analysis on Influencing Factors of NOx Emission in Gas-Fired Heating and Hot Water Combi-Boilers
,”
J. Therm. Sci.
,
30
(
4
), pp.
1151
1159
.
13.
Zhou
,
W.
,
Liu
,
W.
,
Wang
,
Y.
, and
Lv
,
X.
,
2019
, “
Performance Evaluation of Gas-Fired Heating and Hot Water Boilers Based on Principal Component Analysis
,”
J. Eng. Technol.
,
10
(
1
), pp.
65
81
.
14.
Zhou
,
W.
,
Gao
,
W.
,
Ma
,
H.
,
Liu
,
W.
,
Yang
,
L.
, and
Yang
,
L.
,
2022
, “
Steady-State NOx Emission Model for Gas-Fired Heating and Hot Water Combi-Boilers With Factor Analysis and Artificial Neural Network
,”
Emiss. Control Sci. Technol.
,
8
(
3–4
), pp.
182
191
.
15.
Zhou
,
W.
,
Liu
,
W.
,
Wang
,
Y.
,
Lyu
,
X.
, and
Yang
,
L.
,
2021
, “
Analysis of Influencing Factors on NOx Emission in Gas-Fired Heating and Hot Water Combi-Boilers Based on Orthogonal Method
,”
J. Therm. Sci.
,
30
(
3
), pp.
1088
1095
.
16.
Gao
,
W.
,
Wang
,
Y.
,
Yang
,
L.
,
Xu
,
S.
,
Zhou
,
W.
, and
Guo
,
H.
,
2021
, “
Performance Evaluation for Solar Combined Gas Heating System
,”
Renew. Energy
,
167
, pp.
520
529
.
17.
Hassan
,
G.
,
Pourkashanian
,
M.
,
Ingham
,
D.
,
Ma
,
L.
, and
Taylor
,
S.
,
2009
, “
Reduction in Pollutants Emissions From Domestic Boilers—Computational Fluid Dynamics Study
,”
ASME J. Therm. Sci. Eng. Appl.
,
1
(
1
), p.
011007
.
18.
Wang
,
Q.
,
Xiong
,
K.
,
Ying
,
B.
,
Zhang
,
X.
, and
Ren
,
W.
,
2019
, “
Consumption Characteristics of Rural Energies in Karst Area and Their Influence Factors
,”
Chin. J. Agric. Resour. Reg. Plan
,
40
(
3
), pp.
146
157
.
19.
Gong
,
Y.
,
Cai
,
B.
, and
Sun
,
Y.
,
2020
, “
Perceived Fiscal Subsidy Predicts Rural Residential Acceptance of Clean Heating: Evidence From an Indoor-Survey in a Pilot City in China
,”
Energy Policy
,
144
, p.
111687
.
20.
Wagner
,
A.
,
Brien
,
W. O.
, and
Dong
,
B.
,
2018
,
Exploring Occupant Behavior in Buildings Methods and Challenges
,
Springer International Publishing AG
,
Switzerland
.
21.
Kempton
,
W.
,
Feuermann
,
D.
, and
McGarity
,
A. E.
,
1992
, “
I Always Turn It on Super: User Decisions About When and How to Operate Room Air Conditioners
,”
Energy Build.
,
18
(
3–4
), pp.
177
191
.
22.
Walker
,
I. S.
, and
Meier
,
A. K.
,
2008
, “
Residential Thermostats: Comfort Controls in California Homes
,” Lawrence Berkeley National Laboratory, Berkeley, CA, Report No. LBNL-938E.
23.
Parker
,
D.
,
Barkaszi
,
S.
,
Sherwin
,
J.
, and
Richardson
,
C. S.
,
1996
, “
Central Air Conditioner Usage Patterns in Low-Income Housing in a Hot and Humid Climate: Influences on Energy Use and Peak Demand
,”
1996 ACEEE Summer Study on Energy Efficiency in Buildings: Human Dimensions Energy Consumption
,
Washington, DC
,
Aug. 25–31
, pp.
147
160
.
24.
Fabi
,
V.
,
Andersen
,
R. V.
, and
Corgnati
,
S. P.
,
2013
, “
Corgnati, Influence of Occupant’s Heating Set-Point Preferences on Indoor Environmental Quality and Heating Demand in Residential Buildings
,”
HVAC&R Res.
,
19
(
5
), pp.
635
645
.
25.
Luo
,
M.
,
Cao
,
B.
,
Zhou
,
X.
,
Li
,
M.
,
Zhang
,
J.
,
Ouyang
,
Q.
, and
Zhu
,
Y.
,
2014
, “
Can Personal Control Influence Human Thermal Comfort? A Field Study in Residential Buildings in China in Winter
,”
Energy Build.
,
72
(
2
), pp.
411
418
.
26.
Veselý
,
M.
,
Molenaar
,
P.
,
Vos
,
M.
,
Li
,
R.
, and
Zeiler
,
W.
,
2017
, “
Personalized Heating—Comparison of Heaters and Control Modes
,”
Build Environ.
,
112
, pp.
223
232
.
27.
Shao
,
T.
, and
Jin
,
H.
,
2020
, “
A Field Investigation on the Winter Thermal Comfort of Residents in Rural Houses at Different Latitudes of Northeast Severe Cold Regions, China
,”
J. Build. Eng.
,
32
, p.
101476
.
28.
Chen
,
L.
,
Heerink
,
N.
, and
van den Berg
,
M.
,
2006
, “
Energy Consumption in Rural China: A Household Model for Three Villages in Jiangxi Province
,”
Ecol. Econ.
,
58
(
2
), pp.
407
420
.
29.
Jia
,
Y.
,
Li
,
H.
,
Cui
,
X.
, and
Wang
,
Z.
,
2022
, “
Simulation of the Regulation Law of Buildings With Unbalanced Heating by Using the Method of Partition Intermittent Heating
,”
ASME J. Therm. Sci. Eng. Appl.
,
14
(
10
), p.
101003
.
You do not currently have access to this content.