An improved construction of air-separator device, which has radial-vanes embedded within its inlet circumferential opening with their leading-edges facing the moving tips of the fan rotor-blades so as to scoop the tip flow, was investigated with respect to the stall-prevention effect on a low-speed, single-stage, lightly loaded, axial-flow fan. Stall-prevention effects by the separator layout, relative location of the separator to the rotor-blades, and widths of the openings of the air-separator inlet and exit were parametrically surveyed. As far as the particular fan is concerned, the device together with the best relative location has proved to be able to eliminate effectively the stall zone having existed in the original solid-wall characteristics, which has confirmed the promising potential of the device. Guidelines were obtained from the data for optimizing relative locations of the device to the rotor-blades, maximizing the stall-prevention effect of the device, and minimizing the axial size of the device for a required stall-prevention effect, at least for the particular fan and possibly for fans of similar light-load fans. The data suggest the changing internal flow conditions affected by the device conditions.
Skip Nav Destination
Article navigation
April 2010
Research Papers
Improvement of Stalling Characteristics of an Axial-Flow Fan by Radial-Vaned Air-Separators
Nobuyuki Yamaguchi,
Nobuyuki Yamaguchi
Meisei University
, 2-1-1 Hodokubo, Hino-shi, Tokyo 191-8506, Japan
Search for other works by this author on:
Masayuki Ogata,
Masayuki Ogata
Meisei University
, 2-1-1 Hodokubo, Hino-shi, Tokyo 191-8506, Japan
Search for other works by this author on:
Yohei Kato
Yohei Kato
Japan Filter Technology, Ltd.
, I-1-1, Aza Sugise, Tsuhata-machi, Kawakita-gun, Ishikawa Prefecture 929-0454, Japan
Search for other works by this author on:
Nobuyuki Yamaguchi
Meisei University
, 2-1-1 Hodokubo, Hino-shi, Tokyo 191-8506, Japan
Masayuki Ogata
Meisei University
, 2-1-1 Hodokubo, Hino-shi, Tokyo 191-8506, Japan
Yohei Kato
Japan Filter Technology, Ltd.
, I-1-1, Aza Sugise, Tsuhata-machi, Kawakita-gun, Ishikawa Prefecture 929-0454, JapanJ. Turbomach. Apr 2010, 132(2): 021015 (10 pages)
Published Online: January 13, 2010
Article history
Received:
September 5, 2008
Revised:
November 27, 2008
Online:
January 13, 2010
Published:
January 13, 2010
Citation
Yamaguchi, N., Ogata, M., and Kato, Y. (January 13, 2010). "Improvement of Stalling Characteristics of an Axial-Flow Fan by Radial-Vaned Air-Separators." ASME. J. Turbomach. April 2010; 132(2): 021015. https://doi.org/10.1115/1.3104612
Download citation file:
Get Email Alerts
Related Articles
Experimental Aeroacoustic Studies on Improved Tip Configurations for Passive Control of Noise Signatures in Low-Speed Axial Fans
J. Vib. Acoust (December,2009)
Effects of Compact Radial-Vaned Air Separators on Stalling Characteristics of an Axial-Flow Fan
J. Turbomach (April,2010)
Aerodynamic Performance of Blade Tip End-Plates Designed for Low-Noise Operation in Axial Flow Fans
J. Fluids Eng (August,2009)
Experimental Analysis on Tip Leakage and Wake Flow in an Axial Flow Fan According to Flow Rates
J. Fluids Eng (March,2005)
Related Chapters
Fans and Air Handling Systems
Thermal Management of Telecommunications Equipment
Introduction
Turbine Aerodynamics: Axial-Flow and Radial-Flow Turbine Design and Analysis
Aerodynamic Performance Analysis
Axial-Flow Compressors